About this product 10 amp. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC14-10 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150 single location |
Trip Release Method | Thermal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Delay Time In Seconds Per Rated Continuous Current | 4 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Thread Size | 0.469 inches |
Pole Quantity | 1 |
Reset Method | Manual |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Mounting Surface To Terminal End Distance | 1.218 inches nominal |
Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 30 dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location and 5000 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Maximum Continuous Load Current Rating Per Pole | 10 amperes ac single location and 10 amperes dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Internal Trip Release Configuration | Series trip single location |
Inclosure Protection Type For Which Designed | Vibrationproof and corrosion resistant and humidity proof and explosion proof |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Circuit Protection Type | Overcurrent single location |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Body Width | 0.75 inches nominal |
Bushing Length | 0.250 inches nominal |
Body Style | Single pole type |
Body Length | 1.781 inches maximum |
Actuator Position Designation | At pole one |
Actuator Function | Trip-reset |
Unpackaged Unit Weight | 26 grams |
Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
Circuit Breaker
5925-01-093-8477 nsn 2TC145 circuit breaker
Circuit Breaker
2TC143 aircraft circuit breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
Circuit Breaker
15 amp aircraft circuit breaker
Circuit Breaker
2TC14-1 aircraft circuit breaker
15 amp thermal Circuit Breaker with manual reset. Ignition protected & sealed. For the harsh environments of truck, bus, off-road, construction & electric vehicles. Self locking insert for easy mounting. Features: 30VDC or 120VAC, Open and closed constr
Precision, rugged 15 amp manual reset thermal Circuit Breaker for harsh environments. For applications such as military vehicles, etc. Flush mount. Formerly known as M13516/6-2
200 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
Military Spec thermal magnetic Circuit Breaker. Circuit protection unaffected by temperature fluctuations. High vibration resistance and high interrupting capacity. 75 amp.
This item has been added to your cart!