About this product 7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance.
Part Number or Model | 2TC14-7.5 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 1.781 inches maximum |
Body Style | Single pole type |
Body Width | 0.75 inches nominal |
Bushing Length | 0.250 inches nominal |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400.0 single location |
Inclosure Protection Type For Which Designed | Corrosion resistant and explosion proof |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 7.5 amperes ac single location and 7.5 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000.0 ac single location and 5000.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.218 inches nominal |
Thread Size | 0.469 inches |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 30.0 dc single location |
Pole Quantity | 1 |
Reset Method | Manual |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab w/screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25.0 deg celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
Unpackaged Unit Weight | 26.0 grams |
Circuit Breaker
5925-01-093-8477 nsn 2TC145 circuit breaker
Circuit Breaker
2TC143 aircraft circuit breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
Circuit Breaker
15 amp aircraft circuit breaker
Circuit Breaker
Vibration proof and corrosion resistant and humidity proof and explosion proof 2TC1410 circuit breaker
Circuit Breaker
2TC14-1 aircraft circuit breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 7/16'' bushing. Uses minimum space. Light weight. Trip free. 1/2 AMP.
Thermal 5 amp Circuit Breaker. Precision,sealed and ignition protected. Self locking mounting nut for easy installation. Auto reset. Provides excellent over-current protection for harsh environments.
MS141545 circuit breaker
Commercial aircraft Circuit Breaker. Single phase, non compensated, general application. Miniature size. Light weight. Trip free design. 7 1/2 AMP.
This item has been added to your cart!