About this product 3 amp circuit breaker. Single phase. . * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC14-3 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 0.719 inches minimum and 0.781 inches maximum |
Body Style | Single pole type |
Body Width | 0.531 inches minimum and 0.593 inches maximum |
Bushing Length | 0.219 inches minimum and 0.281 inches maximum |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.673 inches minimum and 0.735 inches maximum |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Fungus resistant and moisture resistant |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 3.0 amperes ac single location and 3.0 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000.0 ac single location and 5000.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.281 inches minimum and 1.343 inches maximum |
Thread Size | 0.469 inches |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 30.0 dc single location |
Pole Quantity | 1 |
Precious Material | Silver |
Precious Material And Location | Terminal surfaces silver |
Reset Method | Manual |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab w/screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct single location and 16.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25.0 deg celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Unpackaged Unit Weight | 0.061 pounds |
Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
Circuit Breaker
5925-01-093-8477 nsn 2TC145 circuit breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
Circuit Breaker
15 amp aircraft circuit breaker
Circuit Breaker
Vibration proof and corrosion resistant and humidity proof and explosion proof 2TC1410 circuit breaker
Circuit Breaker
2TC14-1 aircraft circuit breaker
100 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
Water resistant Panel seal boot, fits 7274--2, 7277-2, 2TC2 , 2TC14 and other aircraft and mil spec Circuit Breakers with a 7/16" brushing. Circuit Breaker not included. Durable silicon overmolded seal.
5 amp thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
25 amp circuit breaker
This item has been added to your cart!