About this product 3 amp circuit breaker. Single phase. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC14-3 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Thread Qty Per Inch (tpi) | 32 |
Terminal Type And Quantity | 2 tab with screw |
Storage Type | General purpose warehouse |
Reset Method | Manual |
Precious Material And Location | Terminal surfaces silver |
Pole Quantity | 1 |
Precious Material | Silver |
Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 30 dc single location |
Mounting Surface To Terminal End Distance | 1.281 inches minimum and 1.343 inches maximum |
Mounting Facility Type And Quantity | 1 threaded bushing |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000 ac single location and 5000 dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 3.0 amperes ac single location and 3.0 amperes dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Internal Trip Release Configuration | Series trip single location |
Inclosure Protection Type For Which Designed | Fungus resistant and moisture resistant |
Frequency In Hertz | 400 single location |
Fragility Factor | Moderately rugged |
Circuit Protection Type | Overcurrent single location |
Center To Center Distance Between Terminals Parallel To Length | 0.673 inches minimum and 0.735 inches maximum |
Bushing Length | 0.219 inches minimum and 0.281 inches maximum |
Case Material | Plastic |
Body Width | 0.531 inches minimum and 0.593 inches maximum |
Body Style | Single pole type |
Actuator Position Designation | At pole one |
Body Length | 0.719 inches minimum and 0.781 inches maximum |
Actuator Function | Trip-reset |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Delay Time In Seconds Per Rated Continuous Current | 4 minimum at 200 pct single location and 16.000 maximum at 200 pct single location |
Thread Series Designator | Uns |
Thread Size | 0.469 inches |
Unpackaged Unit Weight | 0.061 pounds |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
Circuit Breaker
Sensata 5925-01-093-8477 nsn 2TC145 circuit breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
Circuit Breaker
15 amp aircraft circuit breaker
Circuit Breaker
Vibration proof and corrosion resistant and humidity proof and explosion proof 2TC1410 circuit breaker
Circuit Breaker
2TC14-1 aircraft circuit breaker
BACC18AD7 circuit breaker
Military Spec thermal magnetic Circuit Breaker. Circuit protection unaffected by temperature fluctuations. High vibration resistance and high interrupting capacity. 100 amp.
25 amp thermal Circuit Breaker with manual reset. Ignition protected.& sealed. For the harsh environments of truck,bus,off-road,construction,& electric vehicles as well as marine. Features: 30VDC or 120VAC, Open and closed construction, Automatic and manu
Thermal 30 amp Circuit Breaker. Precision,sealed and ignition protected. Manual reset. Provides excellent over-current protection for harsh environments. Other ratings available. Call !