About this product 5 amp, single phase. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 2TC14-5 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Unpackaged Unit Weight | 62 grams |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150 single location |
| Trip Release Method | Thermal single location |
| Trip Release Characteristic | Time delay single location |
| Thread Size | 0.469 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 4. minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Thread Series Designator | Uns |
| Reset Method | Manual |
| Storage Type | General purpose warehouse |
| Terminal Type And Quantity | 2 tab with screw |
| Thread Qty Per Inch (tpi) | 32 |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.218 inches nominal |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 30 dc single location |
| Pole Quantity | 1 |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location and 5000 dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 5 amperes ac single location and 5 amperes dc single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Inclosure Protection Type For Which Designed | Fungus resistant |
| Internal Trip Release Configuration | Series trip single location |
| Frequency In Hertz | 400 single location |
| Fragility Factor | Moderately rugged |
| Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Case Material | Plastic |
| Bushing Length | 0.25 inches nominal |
| Body Width | 0.75 inches |
| Body Length | 1.781 inches maximum |
| Actuator Position Designation | At pole one |
| Actuator Function | Trip-reset |
Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
Circuit Breaker
2TC14-4 Circuit Breaker
Circuit Breaker
Sensata Technologies 2TC143 aircraft circuit breaker
Circuit Breaker
2TC14-25 Circuit Breaker
Circuit Breaker
2TC14-20 Circuit Breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
7274-69-3 Circuit Breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 15/32'' bushing. Uses minimum space. Light weight. Trip free. 2 1/2 AMP.
Commercial aircraft Circuit Breaker. Single phase,non compensated,aux contacts,general application. Miniature size. Light weight. Trip free design. 1/2 AMP.
3TC27-30 Circuit Breaker