2TC14-3 Circuit Breaker

Part#: 2TC14-3 NSN: 5925-01-092-5018

About this product 3 amp circuit breaker. Single phase. .

Product Details

Part Number or Model 2TC14-3
Description Circuit Breaker
Schedule B Class
ECCN (Export Control Class) EAR99
Actuator Function Trip-reset
Actuator Position Designation At pole one
Body Length 0.719 inches minimum and 0.781 inches maximum
Body Style Single pole type
Body Width 0.531 inches minimum and 0.593 inches maximum
Bushing Length 0.219 inches minimum and 0.281 inches maximum
Case Material Plastic
Center To Center Distance Between Terminals Parallel To Length 0.673 inches minimum and 0.735 inches maximum
Circuit Protection Type Overcurrent single location
Fragility Factor Moderately rugged
Frequency In Hertz 400 single location
Inclosure Protection Type For Which Designed Fungus resistant and moisture resistant
Internal Trip Release Configuration Series trip single location
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 1 push-pull
Maximum Continuous Load Current Rating Per Pole 3.0 amperes ac single location and 3.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole I 5000.0 ac single location and 5000.0 dc single location
Mounting Facility Type And Quantity 1 threaded bushing
Mounting Surface To Terminal End Distance 1.281 inches minimum and 1.343 inches maximum
Thread Size 0.469 inches
Operating Voltage Type And Rating Per Pole In Volts 120.0 ac single location and 30.0 dc single location
Pole Quantity 1
Precious Material Silver
Precious Material And Location Terminal surfaces silver
Reset Method Manual
Storage Type General purpose warehouse
Terminal Type And Quantity 2 tab w/screw
Thread Qty Per Inch (tpi) 32
Thread Series Designator Uns
Trip Delay Time In Seconds Per Rated Continuous Current 4.000 minimum at 200 pct single location and 16.000 maximum at 200 pct single location
Trip Release Ambient Tempurature Rating 25.0 deg celsius nominal single location
Trip Release Characteristic Time delay single location
Trip Release Method Thermal single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe 138.0 single location
Unpackaged Unit Weight 0.061 pounds

Add to Cart

Up to quantity 20 ships same day.
buy now $49.95
each
Request a quote Call for questions and assistance
  +1 (321) 802-5889
  • NSN (National stock number)
    5925-01-092-5018
  • Manufactured By
    Sensata
  • ECCN (Export Control Class)
    EAR99

Alternate(s)

2TC14 Series Products

see all 2TC14 parts »
2TC14-7.5

Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker

2TC14-5

Circuit Breaker
5925-01-093-8477 nsn 2TC145 circuit breaker

2TC14-2

Circuit Breaker
Sensata 2TC142 aircraft circuit breaker

2TC14-15

Circuit Breaker
15 amp aircraft circuit breaker

2TC14-10

Circuit Breaker
Vibration proof and corrosion resistant and humidity proof and explosion proof 2TC1410 circuit breaker

2TC14-1

Circuit Breaker
2TC14-1 aircraft circuit breaker

More from Sensata

5925-01-111-1315

25 amp,3 phase,miniature,ambient compensated. Light weight,Trip free design AS58091 qualified . Protective Terminal barriers between each phase.

5925-00-350-3069

Commercial 10 amp Klixon thermal Circuit Breaker with auto reset. Ignition protected and sealed. For the harsh environments of truck, bus, off-road, construction, & electric vehicles.

5925-00-295-5460

Thermal 105 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments.

5925-00-985-8269

35 amp, Mil Spec / aerospace Circuit Breaker. Single phase, ambient compensated. Long, trouble free operation: 20,000 operating cycles High vibration resistance.

Compare Now »
Clear | Hide
Notice

Item added to cart

This item has been added to your cart!