About this product 3 amp circuit breaker. Single phase. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 2TC14-3 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Case Material | Plastic |
| Unpackaged Unit Weight | 0.061 pounds |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138 single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Trip Delay Time In Seconds Per Rated Continuous Current | 4 minimum at 200 pct single location and 16.000 maximum at 200 pct single location |
| Thread Series Designator | Uns |
| Thread Size | 0.469 inches |
| Thread Qty Per Inch (tpi) | 32 |
| Storage Type | General purpose warehouse |
| Terminal Type And Quantity | 2 tab with screw |
| Pole Quantity | 1 |
| Precious Material | Silver |
| Precious Material And Location | Terminal surfaces silver |
| Reset Method | Manual |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 30 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.281 inches minimum and 1.343 inches maximum |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000 ac single location and 5000 dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 3 amperes ac single location and 3 amperes dc single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Fungus resistant and moisture resistant |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400 single location |
| Circuit Protection Type | Overcurrent single location |
| Bushing Length | 0.219 inches minimum and 0.281 inches maximum |
| Center To Center Distance Between Terminals Parallel To Length | 0.673 inches minimum and 0.735 inches maximum |
| Body Width | 0.531 inches minimum and 0.593 inches maximum |
| Body Style | Single pole type |
| Body Length | 0.719 inches minimum and 0.781 inches maximum |
| Actuator Position Designation | At pole one |
| Actuator Function | Trip-reset |
Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
Circuit Breaker
Sensata 2TC145 circuit breaker
Circuit Breaker
2TC14-4 Circuit Breaker
Circuit Breaker
2TC14-25 Circuit Breaker
Circuit Breaker
2TC14-20 Circuit Breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
Thermal 105 amp Circuit Breaker. Ignition protected and sealed. Manual reset. Over-current protection for harsh environments, vehicle, electric vehicle, battery chargers, marine, etc.
10 amp circuit breaker
2TC27-4 Circuit Breaker
7270-1-10 Circuit Breaker
This item has been added to your cart!