About this product 7274-11-2-1/2 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-11-2-1/2 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Arc Quenching Method | Air |
| Body Length | 0.562 inches nominal |
| Body Style | Single pole type |
| Body Width | 0.750 inches nominal |
| Bushing Length | 0.250 inches nominal |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Shockproof |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.0 amperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800.0 ac single location and 2000.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.707 inches nominal |
| Thread Size | 0.469 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 28.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Storage Type | General purpose warehouse |
| Terminal Type And Quantity | 2 tab with screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location |
| Unpackaged Unit Weight | 38.0 grams |
Military/aerospace Circuit Breaker. Thermal 3 phase, miniature, ambient compensated. Trip free and lightweight. Vibration pads improve mounting stability. 10 amps.
35 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC single
Thermal 35 amp Circuit Breaker. Ignition protected and sealed.. Auto reset. Over-current protection for harsh environments,vehicle,electric vehicle,battery chargers,marine,etc..
7274-4-1/2 Circuit Breaker