About this product 1 amp, single phase, circuit breaker. Aircraft use. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC14-1 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Thread Size | 0.469 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
Thread Series Designator | Uns |
Thread Qty Per Inch (tpi) | 32 |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Reset Method | Manual |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 30.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.218 inches nominal |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location and 5000.0 dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 1.0 amperes ac single location and 1.0 amperes dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Internal Trip Release Configuration | Series trip single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Corrosion resistant and vibrationproof |
Circuit Protection Type | Overcurrent single location |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Bushing Length | 0.25 inches nominal |
Unpackaged Unit Weight | 62.0 grams |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Body Width | 0.75 inches nominal |
Actuator Position Designation | At pole one |
Body Length | 1.781 inches maximum |
Actuator Function | Trip reset |
Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
Circuit Breaker
5925-01-093-8477 nsn 2TC145 circuit breaker
Circuit Breaker
2TC143 aircraft circuit breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
Circuit Breaker
15 amp aircraft circuit breaker
Circuit Breaker
Vibration proof and corrosion resistant and humidity proof and explosion proof 2TC1410 circuit breaker
3 AMP thermal commercial aircraft Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
Thermal 25 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments.
Commercial aircraft Circuit Breaker. Thermal 3 phase, miniature, ambient compensated. Trip free and lightweight. Vibration pads improve mounting stability. 20 amps
7271 thermal Circuit Breakers are designed to utilize less space behind the Panel while protecting wire & Cable in aircraft & ground support equipment. Push button style. 5 amps. Similar to 7271-8-5 but this version has a plate mount vs. the neck mount.
This item has been added to your cart!