About this product 1 amp, single phase, circuit breaker. Aircraft use. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC14-1 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Thread Size | 0.469 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
Thread Series Designator | Uns |
Thread Qty Per Inch (tpi) | 32 |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Reset Method | Manual |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 30.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.218 inches nominal |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location and 5000.0 dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 1.0 amperes ac single location and 1.0 amperes dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Internal Trip Release Configuration | Series trip single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Corrosion resistant and vibrationproof |
Circuit Protection Type | Overcurrent single location |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Bushing Length | 0.25 inches nominal |
Unpackaged Unit Weight | 62.0 grams |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Body Width | 0.75 inches nominal |
Actuator Position Designation | At pole one |
Body Length | 1.781 inches maximum |
Actuator Function | Trip reset |
Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
Circuit Breaker
Sensata 5925-01-093-8477 nsn 2TC145 circuit breaker
Circuit Breaker
2TC14-4 Circuit Breaker
Circuit Breaker
Sensata Technologies 2TC143 aircraft circuit breaker
Circuit Breaker
2TC14-25 Circuit Breaker
Circuit Breaker
2TC14-20 Circuit Breaker
Thermal 5 amp Circuit Breaker. Precision,sealed and ignition protected. Self locking mounting nut for easy installation. Auto reset. Provides excellent over-current protection for harsh environments.
7 1/2 amp thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
Thermal 70 amp Circuit Breaker. Ignition protected and sealed.. Auto reset. Over-current protection for harsh environments,vehicle,electric vehicle,battery chargers,marine,etc..
Thermal 50 amp Circuit Breaker. Precision,sealed and ignition protected. Manual reset. Self locking mounting nut for easy installation. Provides excellent over-current protection for harsh environments.
This item has been added to your cart!