About this product 1 amp, single phase, circuit breaker. Aircraft use. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC14-1 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Thread Size | 0.469 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
Thread Series Designator | Uns |
Thread Qty Per Inch (tpi) | 32 |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Reset Method | Manual |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 30.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.218 inches nominal |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location and 5000.0 dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 1.0 amperes ac single location and 1.0 amperes dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Internal Trip Release Configuration | Series trip single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Corrosion resistant and vibrationproof |
Circuit Protection Type | Overcurrent single location |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Bushing Length | 0.25 inches nominal |
Unpackaged Unit Weight | 62.0 grams |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Body Width | 0.75 inches nominal |
Actuator Position Designation | At pole one |
Body Length | 1.781 inches maximum |
Actuator Function | Trip reset |
Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
Circuit Breaker
Sensata 5925-01-093-8477 nsn 2TC145 circuit breaker
Circuit Breaker
2TC143 aircraft circuit breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
Circuit Breaker
15 amp aircraft circuit breaker
Circuit Breaker
Vibration proof and corrosion resistant and humidity proof and explosion proof 2TC1410 circuit breaker
Thermal 80 amp Circuit Breaker. Precision,sealed and ignition protected. Manual reset. Provides excellent over-current protection for harsh environments.
100 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
Commercial aircraft Circuit Breaker. Single phase, non compensated, general application. Miniature size. Light weight. Trip free design. 7 1/2 AMP.
25 amp thermal Circuit Breaker with manual reset. Ignition protected.& sealed. For the harsh environments of truck,bus,off-road,construction,& electric vehicles as well as marine. Features: 30VDC or 120VAC, Open and closed construction, Automatic and manu