About this product Trip free, 2 screw terminal, aircraft use. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | MS25244-5 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Thread Size | 0.469 inches |
| Thread Series Designator | Uns |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 2 screw |
| Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
| Specification Data | 96906-ms25244 government standard |
| Reset Method | Manual |
| Pole Quantity | 1 |
| Mounting Surface To Terminal End Distance | 1.812 inches maximum |
| Operating Voltage Type And Rating Per Pole In Volts | 115 ac single location and 28 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
| Maximum Continuous Load Current Rating Per Pole | 5 amperes ac single location and 5 amperes dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Frequency In Hertz | 400 single location |
| Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Circuit Protection Type | Overcurrent single location |
| Bushing Length | 0.250 inches nominal |
| Case Material | Metal |
| Center To Center Distance Between Terminals Parallel To Length | 0.703 inches nominal |
| Body Style | Single pole type |
| Body Width | 0.750 inches maximum |
| Body Length | 1.094 inches maximum |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Trip Delay Time In Seconds Per Rated Continuous Current | 15 minimum at 200 pct single location and 55.000 maximum at 200 pct single location and 2.000 minimum at 400 pct single location and 7.000 maximum at 400 pct single location |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Circuit Breaker
MS25244712 circuit breaker
Circuit Breaker
5925-00-686-3299 nsn trip free MS2524435 circuit breaker
Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker
Circuit Breaker
MS25244-20 Circuit Breaker
Circuit Breaker
MS25244-15 Circuit Breaker
3SB4-1-50 Simulator Circuit Breaker
Mil spec to MS24510-B-7 1/2, Sensata Klixon thermal Circuit Breakers are designed to utilize less space behind the Panel while protecting wire & Cable in aircraft & ground support equipment. Push button style. 7 1/2 amps. Similar to 7271-8-7 1/2 but this
7277-1-15 Circuit Breaker
30 amp,3 phase,miniature,ambient compensated. Light weight,Trip free design AS58091 qualified . Protective Terminal barriers between each phase.
This item has been added to your cart!