About this product Single phase, 30 amp. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS25244-30 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 2.189 inches maximum |
Body Style | Single pole type |
Body Width | 0.750 inches maximum |
Bushing Length | 0.235 inches minimum and 0.265 inches maximum |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches maximum |
Circuit Protection Type | Overcurrent single location |
Distance Between Centerlines Of Mounting Facilities Parallel To | 1.796 inches minimum and 1.828 inches maximum |
Frequency In Hertz | 400.0 single location |
Inclosure Protection Type For Which Designed | Shock resistant and vibration resistant |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 30 amperes ac single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location |
Mounting Facility Type And Quantity | 2 threaded hole |
Mounting Surface To Terminal End Distance | 2 inches maximum |
Thread Size | 0.138 inches |
Operating Voltage Type And Rating Per Pole In Volts | 200.0 ac single location |
Pole Quantity | 1 |
Reset Method | Manual |
Specification Data | 96906-ms25244 government standard |
Terminal Type And Quantity | 2 tab, solder lug |
Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Unc |
Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 200.0 single location |
Ultimate Trip Time Per Pole In Seconds | 138.000 nominal single location |
Circuit Breaker
MS25244712 circuit breaker
Circuit Breaker
5925-00-686-3297 nsn MS252445 circuit breaker
Circuit Breaker
5925-00-686-3299 nsn trip free MS2524435 circuit breaker
Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker
Circuit Breaker
MS2524420 circuit breaker
Circuit Breaker
MS2524410 circuit breaker
Thermal Circuit Breaker. Sealed & ignition protected, hi amp, rugged. 200 amps. Automatic reset. Harness protection for heavy trucks, construction equipment, buses, off road vehicles. Formerly known as AA55571/08-002, M13516/8-7, MS39069-2.
AP61R382961 circuit breaker
7271 thermal Circuit Breakers are designed to utilize less space behind the Panel while protecting wire & Cable in aircraft & ground support equipment. Push button style. 15 amps. Similar to 7271-8-10 but this version has a plate mount vs. the neck mount.
8 amp thermal Circuit Breaker with auto reset. Ignition protected & sealed. For the harsh environments of truck, bus, off-road, construction & electric vehicles.