About this product MS25244-20 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | MS25244-20 |
| Description | Circuit Breaker |
| Schedule B Class | 8536.20.0040 |
| ECCN (Export Control Class) | EAR99 |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Trip Delay Time In Seconds Per Rated Continuous Current | 15 minimum at 200 pct all locations and 55.000 maximum at 200 pct all locations |
| Thread Size | 0.469 inches |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Terminal Type And Quantity | 2 tab with screw |
| Reset Method | Manual |
| Storage Type | General purpose warehouse |
| Pole Quantity | 1 |
| Primary Uses | Aircraft electrical systems, avionics, and military hardware |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
| Mounting Surface To Terminal End Distance | 1.840 inches maximum |
| Mounting Facility Type And Quantity | 1 threaded bushing with panel seal |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500.0 ac single location and 6000.0 dc single location |
| Manual Actuator Type And Quantity | 1 toggle |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Shock resistant and vibration resistant |
| Design Type | Single-pole, thermal, push-pull, trip-free |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400 single location |
| Current Rating | 20 amps |
| Circuit Protection Type | Overcurrent single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Case Material | Metal |
| Bushing Length | 0.235 inches minimum and 0.265 inches maximum |
| Body Style | Single pole type |
| Body Width | 0.75 inches maximum |
| Body Length | 1.094 inches maximum |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138 single location |
| Unpackaged Unit Weight | 0.1 pounds |
Circuit Breaker
MS25244712 circuit breaker
Circuit Breaker
MS25244-5 Circuit Breaker, 5925-00-686-3297
Circuit Breaker
5925-00-686-3299 nsn trip free MS2524435 circuit breaker
Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker
Circuit Breaker
MS25244-15 Circuit Breaker
Three Phase aircraft Circuit Breaker, lightweight, high performance, trip free design. rated 20 amps at 115VAC/ 400Hz. Airbus ASNE0459-200. Other amp ratings available.
Thermal 4 amp Circuit Breaker. Precision, sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments.
Commercial 10 amp Klixon thermal Circuit Breaker with auto reset. Ignition protected and sealed. For the harsh environments of truck, bus, off-road, construction, & electric vehicles.
Circuit Breaker. Military Spec thermal magnetic Circuit Breaker. Circuit protection unaffected by temperature fluctuations. High vibration resistance and high interrupting capacity. 70 amp.
This item has been added to your cart!