About this product MS25244-20 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS25244-20 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 1.094 inches maximum |
Body Style | Single pole type |
Body Width | 0.750 inches maximum |
Bushing Length | 0.235 inches minimum and 0.265 inches maximum |
Case Material | Metal |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400.0 single location |
Inclosure Protection Type For Which Designed | Shock resistant and vibration resistant |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 toggle |
Maximum Continuous Load Current Rating Per Pole | 20 amperes ac single location and 20 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500.0 ac single location and 6000.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing with panel seal |
Mounting Surface To Terminal End Distance | 1.840 inches maximum |
Thread Size | 0.469 inches |
Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
Pole Quantity | 1 |
Reset Method | Manual |
Specification Data | 96906-ms25244 government standard |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 minimum at 200 pct all locations and 55.000 maximum at 200 pct all locations |
Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Unpackaged Unit Weight | 0.100 pounds |
Circuit Breaker
MS25244712 circuit breaker
Circuit Breaker
5925-00-686-3297 nsn MS252445 circuit breaker
Circuit Breaker
5925-00-686-3299 nsn trip free MS2524435 circuit breaker
Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker
Circuit Breaker
MS25244-15 Circuit Breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 15/32'' bushing. Uses minimum space. Light weight. Trip free. 1/2 AMP.
7274-4-4 Circuit Breaker
7274-11-3 Circuit Breaker
30 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC single
This item has been added to your cart!