About this product MS25244-10 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS25244-10 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Trip Release Characteristic | Time delay single location |
Trip Release Ambient Tempurature Rating | 25.0 deg celsius nominal single location |
Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location |
Thread Series Designator | Uns |
Thread Size | 0.469 inches |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Thread Qty Per Inch (tpi) | 32 |
Specification Data | 96906-ms25244-10 government standard |
Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
Reset Method | Manual |
Pole Quantity | 1 |
Mounting Surface To Terminal End Distance | 1.840 inches maximum |
Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Inclosure Protection Type For Which Designed | Hermetically sealed and shock resistant and vibration resistant |
Maximum Continuous Load Current Rating Per Pole | 10 amperes ac single location and 10 amperes dc single location |
Internal Trip Release Configuration | Series trip single location |
Frequency In Hertz | 400 single location |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Case Material | Metal |
Center To Center Distance Between Terminals Parallel To Length | 0.673 inches minimum and 0.735 inches maximum |
Body Width | 0.750 inches maximum |
Bushing Length | 0.235 inches minimum and 0.265 inches maximum |
Body Style | Single pole type |
Actuator Position Designation | At pole one |
Body Length | 1.094 inches maximum |
Actuator Function | Trip-reset |
Unpackaged Unit Weight | 1.813 pounds |
Circuit Breaker
MS25244712 circuit breaker
Circuit Breaker
5925-00-686-3297 nsn MS252445 circuit breaker
Circuit Breaker
5925-00-686-3299 nsn trip free MS2524435 circuit breaker
Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker
Circuit Breaker
MS25244-20 Circuit Breaker
35 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC single
6TC2-7-1/2 Circuit Breaker
35 amp, Mil Spec / aerospace Circuit Breaker. Single phase, ambient compensated. Long, trouble free operation: 20,000 operating cycles High vibration resistance.
15 amp circuit breaker