MS25244-35 Circuit Breaker

Part#: MS25244-35 NSN: 5925-00-686-3299

About this product single phase, 35 amp, Milspec. * Manufacturer certifications are shipped with your order FREE of charge

Product Images
MS25244-35 MS25244-35 MS25244-35 MS25244-35 MS25244-35 MS25244-35

Product Details

Part Number or Model MS25244-35
Description Circuit Breaker
Schedule B Class
ECCN (Export Control Class) EAR99
Actuator Function Trip-reset
Actuator Position Designation At pole one
Body Length 1.094 inches maximum
Body Style Single pole type
Body Width 0.75 inches maximum
Bushing Length 0.235 inches minimum and 0.265 inches maximum
Case Material Metal
Center To Center Distance Between Terminals Parallel To Length 0.673 inches minimum and 0.735 inches maximum
Circuit Protection Type Overcurrent single location
Fragility Factor Moderately rugged
Frequency In Hertz 400 single location
Inclosure Protection Type For Which Designed Hermetically sealed and shock resistant and vibration resistant
Internal Trip Release Configuration Series trip single location
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 1 push-pull
Maximum Continuous Load Current Rating Per Pole 35 amps ac single location and 35 amps dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole I 3500 ac single location and 6000 dc single location
Mounting Facility Type And Quantity 1 threaded bushing with panel seal
Mounting Surface To Terminal End Distance 1.840 inches maximum
Thread Size 0.469 inches
Operating Voltage Type And Rating Per Pole In Volts 115.0 ac single location and 28.0 dc single location
Pole Quantity 1
Reset Method Manual
Specification Data 96906-ms25244 government standard
Storage Type General purpose warehouse
Terminal Type And Quantity 2 tab with screw
Test Data Document 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as
Thread Qty Per Inch (tpi) 32
Thread Series Designator Uns
Trip Delay Time In Seconds Per Rated Continuous Current 15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location
Trip Release Ambient Tempurature Rating 25.0 degree celsius nominal single location
Trip Release Characteristic Time delay single location
Trip Release Method Thermal single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe 138.0 single location
Unpackaged Unit Weight 1.813 pounds

Add to Cart

Up to quantity 4 ships same day.
buy now $99.95
each
Request a quote Call for questions and assistance
  +1 (321) 802-5889
  • NSN (National stock number)
    5925-00-686-3299
  • Manufactured By
    Sensata
  • ECCN (Export Control Class)
    EAR99

Alternate(s)

MS25244 Series Products

see all MS25244 parts »
MS25244-7-1/2

Circuit Breaker
MS25244712 circuit breaker

MS25244-5

Circuit Breaker
5925-00-686-3297 nsn MS252445 circuit breaker

MS25244-30

Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker

MS25244-25

Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker

MS25244-20

Circuit Breaker
MS2524420 circuit breaker

MS25244-10

Circuit Breaker
MS2524410 circuit breaker

More from Sensata

MS25244-10

MS2524410 circuit breaker

MS25244-30

5925-01-227-4047 nsn milspec MS2524430 circuit breaker

5925-00-886-5440

20 amp thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.

5925-01-578-4594

Aircraft Circuit Breaker. Miniature, lightweight,3-phase, ambient compensated. 6TC6-15 is Trip Free and rated at 15 amps. Meets BACC18AC15 spec.

Compare Now »
Clear | Hide
Notice

Item added to cart

This item has been added to your cart!