About this product single phase, 35 amp, Milspec. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS25244-35 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 1.094 inches maximum |
Body Style | Single pole type |
Body Width | 0.75 inches maximum |
Bushing Length | 0.235 inches minimum and 0.265 inches maximum |
Case Material | Metal |
Center To Center Distance Between Terminals Parallel To Length | 0.673 inches minimum and 0.735 inches maximum |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Hermetically sealed and shock resistant and vibration resistant |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 35 amps ac single location and 35 amps dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing with panel seal |
Mounting Surface To Terminal End Distance | 1.840 inches maximum |
Thread Size | 0.469 inches |
Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
Pole Quantity | 1 |
Reset Method | Manual |
Specification Data | 96906-ms25244 government standard |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Unpackaged Unit Weight | 1.813 pounds |
Circuit Breaker
MS25244712 circuit breaker
Circuit Breaker
5925-00-686-3297 nsn MS252445 circuit breaker
Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker
Circuit Breaker
MS2524420 circuit breaker
Circuit Breaker
MS2524410 circuit breaker
MS2524410 circuit breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
20 amp thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
Aircraft Circuit Breaker. Miniature, lightweight,3-phase, ambient compensated. 6TC6-15 is Trip Free and rated at 15 amps. Meets BACC18AC15 spec.
This item has been added to your cart!