About this product single phase, 35 amp, Milspec. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS25244-35 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 1.094 inches maximum |
Body Style | Single pole type |
Body Width | 0.75 inches maximum |
Bushing Length | 0.235 inches minimum and 0.265 inches maximum |
Case Material | Metal |
Center To Center Distance Between Terminals Parallel To Length | 0.673 inches minimum and 0.735 inches maximum |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Hermetically sealed and shock resistant and vibration resistant |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 35 amps ac single location and 35 amps dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing with panel seal |
Mounting Surface To Terminal End Distance | 1.840 inches maximum |
Thread Size | 0.469 inches |
Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
Pole Quantity | 1 |
Reset Method | Manual |
Specification Data | 96906-ms25244 government standard |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Unpackaged Unit Weight | 1.813 pounds |
Circuit Breaker
MS25244712 circuit breaker
Circuit Breaker
5925-00-686-3297 nsn MS252445 circuit breaker
Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker
Circuit Breaker
MS2524420 circuit breaker
Circuit Breaker
MS2524410 circuit breaker
Thermal 70 amp Circuit Breaker. Ignition protected and sealed.. Auto reset. Over-current protection for harsh environments,vehicle,electric vehicle,battery chargers,marine,etc..
5925-00-886-5436 nsn 2TC215 circuit breaker milspec part number MS3320-15
Military/aerospace Circuit Breaker. Thermal 3 phase, miniature, ambient compensated. Trip free and lightweight. Vibration pads improve mounting stability. 7 1/2 amps.
200 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
This item has been added to your cart!