About this product 7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 2TC14-7.5 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Unpackaged Unit Weight | 26.0 grams |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
| Trip Release Method | Thermal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Delay Time In Seconds Per Rated Continuous Current | 4 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Thread Series Designator | Uns |
| Thread Size | 0.469 inches |
| Terminal Type And Quantity | 2 tab with screw |
| Thread Qty Per Inch (tpi) | 32 |
| Storage Type | General purpose warehouse |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 30 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Mounting Surface To Terminal End Distance | 1.218 inches nominal |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location and 5000 dc single location |
| Maximum Continuous Load Current Rating Per Pole | 7.5 amperes ac single location and 7.5 amperes dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Inclosure Protection Type For Which Designed | Corrosion resistant and explosion proof |
| Frequency In Hertz | 400 single location |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
| Body Width | 0.75 inches nominal |
| Bushing Length | 0.25 inches nominal |
| Body Style | Single pole type |
| Body Length | 1.781 inches maximum |
| Actuator Position Designation | At pole one |
| Actuator Function | Trip-reset |
Circuit Breaker
Sensata 2TC145 circuit breaker
Circuit Breaker
2TC14-4 Circuit Breaker
Circuit Breaker
Sensata Technologies 2TC143 aircraft circuit breaker
Circuit Breaker
2TC14-25 Circuit Breaker
Circuit Breaker
2TC14-20 Circuit Breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker
50 amp Mil Spec / aerospace Circuit Breaker. Single phase, ambient compensated. Long, trouble free operation: 20,000 operating cycles High vibration resistance. Also available in 2 1/2 to 35 amps.
15 amp thermal Circuit Breaker with manual reset. Ignition protected & sealed. For the harsh environments of truck, bus, off-road, construction & electric vehicles as well as marine. Features: 30VDC or 120VAC, Open and closed construction, Automatic and m
Sensata 2TC22 circuit breaker
Circuit Breaker. Precision, rugged 15 amp manual reset thermal Circuit Breaker for harsh environments. For applications such as military vehicles, etc. Neck bushing mount style.
This item has been added to your cart!