About this product 5 amp, single phase. * Manufacturer certifications are shipped with your order FREE of charge
													
													
													
													
													
											| Part Number or Model | 2TC14-5 | 
| Description | Circuit Breaker | 
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 | 
| Unpackaged Unit Weight | 62 grams | 
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150 single location | 
| Trip Release Method | Thermal single location | 
| Trip Release Characteristic | Time delay single location | 
| Thread Size | 0.469 inches | 
| Trip Delay Time In Seconds Per Rated Continuous Current | 4. minimum at 200 pct single location and 20.000 maximum at 200 pct single location | 
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location | 
| Thread Series Designator | Uns | 
| Reset Method | Manual | 
| Storage Type | General purpose warehouse | 
| Terminal Type And Quantity | 2 tab with screw | 
| Thread Qty Per Inch (tpi) | 32 | 
| Mounting Facility Type And Quantity | 1 threaded bushing | 
| Mounting Surface To Terminal End Distance | 1.218 inches nominal | 
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 30 dc single location | 
| Pole Quantity | 1 | 
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location and 5000 dc single location | 
| Manual Actuator Type And Quantity | 1 push-pull | 
| Maximum Continuous Load Current Rating Per Pole | 5 amperes ac single location and 5 amperes dc single location | 
| Main Contact Tripping Mechanism Type | Trip free | 
| Inclosure Protection Type For Which Designed | Fungus resistant | 
| Internal Trip Release Configuration | Series trip single location | 
| Frequency In Hertz | 400 single location | 
| Fragility Factor | Moderately rugged | 
| Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal | 
| Circuit Protection Type | Overcurrent single location | 
| Case Material | Plastic | 
| Bushing Length | 0.25 inches nominal | 
| Body Width | 0.75 inches | 
| Body Length | 1.781 inches maximum | 
| Actuator Position Designation | At pole one | 
| Actuator Function | Trip-reset | 
			Circuit Breaker
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker 
Circuit Breaker
2TC14-4 Circuit Breaker
Circuit Breaker
Sensata Technologies 2TC143 aircraft circuit breaker 
Circuit Breaker
2TC14-25 Circuit Breaker
Circuit Breaker
2TC14-20 Circuit Breaker
Circuit Breaker
Sensata 2TC142 aircraft circuit breaker 
5925-00-686-3299 nsn trip free MS2524435 circuit breaker
27515-6 Circuit Breaker Insert
4 amp thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
6752-100-70 Circuit Breaker
This item has been added to your cart!