About this product Single phase, 35 amp, trip free, 3TC2-35. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | MS14105-35 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Thread Size | 0.438 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.0 minimum at 200 pct and 35.000 maximum at 200 pct single location |
| Terminal Type And Quantity | 2 tab with screw |
| Storage Type | General purpose warehouse |
| Specification Data | 81349-ms14105/35 government standard |
| Reset Method | Manual |
| Pole Quantity | 1 |
| Operating Voltage Type And Rating Per Pole In Volts | 200 ac and 115 dc single location |
| Mounting Surface To Terminal End Distance | 1.343 inches maximum |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location |
| Maximum Continuous Load Current Rating Per Pole | 35.0 amperes ac and 35.0 amperes dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Vibration resistant and shock resistant |
| Frequency In Hertz | 400 single location |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
| Body Width | 0.781 inches maximum |
| Bushing Length | 0.25 inches nominal |
| Body Style | Single pole type |
| Actuator Position Designation | At pole one |
| Body Length | 1.094 inches maximum |
| Actuator Function | Trip-reset |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
| Unpackaged Unit Weight | 0.062 pounds |
Circuit Breaker
5925-01-075-6783 nsn milspec MS1410530 circuit breaker 3TC2-30
Circuit Breaker
MS14105-25 Circuit Breaker, 5925-01-088-6587
Thermal 50 amp Circuit Breaker. Ignition protected and sealed.. Auto reset. Over-current protection for harsh environments, vehicle, electric vehicle, battery chargers, marine, etc..
Commercial aircraft Circuit Breaker. Thermal 3 phase, miniature, ambient compensated. Trip free and lightweight. Vibration pads improve mounting stability. 2 amps.
Commercial aircraft Circuit Breaker. Single phase, non compensated, general application. Miniature size. Light weight. Trip free design. 7 1/2 AMP.
3 amp thermal Circuit Breaker with manual reset. Ignition protected.& sealed. For the harsh environments of truck, bus, off-road, construction & electric vehicles as well as marine. Features: 30VDC or 120VAC, Open and closed construction, Automatic and
This item has been added to your cart!