About this product Single phase, 35 amp, trip free, 3TC2-35. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS14105-35 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Thread Series Designator | Un |
Thread Qty Per Inch (tpi) | 32 |
Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Specification Data | 81349-ms14105/35 government standard |
Reset Method | Manual |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 200 ac and 115 dc single location |
Mounting Surface To Terminal End Distance | 1.343 inches maximum |
Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac single location |
Maximum Continuous Load Current Rating Per Pole | 35.0 amperes ac and 35.0 amperes dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Main Contact Tripping Mechanism Type | Trip free |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Vibration resistant and shock resistant |
Internal Trip Release Configuration | Series trip single location |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Body Width | 0.781 inches maximum |
Bushing Length | 0.25 inches nominal |
Body Style | Single pole type |
Actuator Position Designation | At pole one |
Body Length | 1.094 inches maximum |
Actuator Function | Trip-reset |
Thread Size | 0.438 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 2.0 minimum at 200 pct and 35.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Unpackaged Unit Weight | 0.062 pounds |
Circuit Breaker
5925-01-075-6783 nsn milspec MS1410530 circuit breaker 3TC2-30
Circuit Breaker
25 amp circuit breaker