About this product Boeing spec aircraft Circuit Breaker 2 1/2 amps. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 5925-01-142-7773 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 0.750 inches nominal |
Body Style | Single pole type |
Body Width | 0.562 inches nominal |
Bushing Length | 0.250 inches nominal |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.50 inches nominal |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400.0 single location |
Inclosure Protection Type For Which Designed | Corrosion resistant and explosion proof and dusttight and humidity resistant and sandtight and shockproof and vibrationproof |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push button |
Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.5 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500.0 ac single location and 2500.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
Mounting Surface To Terminal End Distance | 1.312 inches nominal |
Thread Size | 0.438 inches |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 30.0 dc single location |
Pole Quantity | 1 |
Reset Method | Manual |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab w/screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Un |
Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 minimum at 200 pct single location and 35.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25.0 deg celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Unpackaged Unit Weight | 25.0 grams |
Circuit Breaker
7.5 amp circuit breaker
Circuit Breaker
5 amp circuit breaker
Circuit Breaker
2.5 amp circuit breaker
Circuit Breaker
2 amp circuit breaker
Circuit Breaker
15 amp circuit breaker
Circuit Breaker
10 amp circuit breaker
Circuit Breaker. 35 amp,3 phase,miniature,ambient compensated. Light weight,Trip free design AS58091 qualified . Protective Terminal barriers between each phase.
Precision rugged 2 amp manual reset thermal Circuit Breaker for harsh environments.For applications such as military vehicles,etc.
7274225 circuit breaker
175 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
This item has been added to your cart!