About this product 15 amp circuit breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 2TC6-15 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 2 tab with screw |
| Storage Type | General purpose warehouse |
| Reset Method | Manual |
| Pole Quantity | 1 |
| Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 28.0 dc single location |
| Mounting Surface To Terminal End Distance | 1.630 inches maximum |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
| Maximum Continuous Load Current Rating Per Pole | 5 amperes ac single location and 5 amperes dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Dustproof and sandtight and corrosion resistant and moisture resistant and explosion proof |
| Frequency In Hertz | 400.0 single location |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.469 inches minimum and 0.531 inches maximum |
| Case Material | Plastic |
| Bushing Length | 0.219 inches minimum and 0.281 inches maximum |
| Body Style | Single pole type |
| Body Width | 0.719 inches minimum and 0.781 inches maximum |
| Body Length | 0.880 inches maximum |
| Actuator Position Designation | At pole one |
| Arc Quenching Method | Air |
| Actuator Function | Trip-reset |
| Thread Series Designator | Uns |
| Thread Size | 0.438 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 5.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
| Unpackaged Unit Weight | 0.090 pounds |
Circuit Breaker
7.5 amp circuit breaker
Circuit Breaker
Sensata 5 amp circuit breaker, 5925-01-518-6683
Circuit Breaker
2TC6-3 Circuit Breaker
Circuit Breaker
2.5 amp circuit breaker
Circuit Breaker
2 amp circuit breaker
Circuit Breaker
10 amp circuit breaker
7270-1-35 Circuit Breaker
Thermal military spec Circuit Breaker, single phase, miniature ambient compensated. High performance,trip-free "state of the art" protection. 25 amp.
200 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
15 amp, 3 phase, miniature, ambient compensated. Light weight, Trip free design AS58091 qualified . Protective Terminal barriers between each phase.
This item has been added to your cart!