About this product Boeing spec aircraft Circuit Breaker 2 1/2 amps. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 5925-01-142-7773 |
| Description | Circuit Breaker |
| Schedule B Class | 8536.20.0040 |
| ECCN (Export Control Class) | EAR99 |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 2 tab with screw |
| Storage Type | General purpose warehouse |
| Reset Method | Manual |
| Pole Quantity | 1 |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 30 dc single location |
| Mounting Surface To Terminal End Distance | 1.312 inches nominal |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500 ac single location and 2500 dc single location |
| Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.5 amperes dc single location |
| Manual Actuator Type And Quantity | 1 push button |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Corrosion resistant and explosion proof and dusttight and humidity resistant and sandtight and shockproof and vibrationproof |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.50 inches nominal |
| Body Width | 0.562 inches nominal |
| Bushing Length | 0.250 inches nominal |
| Body Style | Single pole type |
| Actuator Position Designation | At pole one |
| Body Length | 0.750 inches nominal |
| Actuator Function | Trip-reset |
| Thread Series Designator | Un |
| Thread Size | 0.438 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 3 minimum at 200 pct single location and 35.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
| Unpackaged Unit Weight | 25.0 grams |
Circuit Breaker
7.5 amp circuit breaker
Circuit Breaker
Sensata 5 amp circuit breaker, 5925-01-518-6683
Circuit Breaker
2TC6-3 Circuit Breaker
Circuit Breaker
2.5 amp circuit breaker
Circuit Breaker
2 amp circuit breaker
Circuit Breaker
15 amp circuit breaker
25 AMP mil/aero thermal Circuit Breaker. Klixon 9TC series Circuit Breakers provide ambient compensated circuit protection in a lightweight, sub-miniature package size. The three phase integrally linked design provides overcurrent protection in the event
Thermal 150 amp Circuit Breaker. Precision,sealed and ignition protected. Manual reset. Self locking mounting nut for easy installation. Provides excellent over-current protection for harsh environments. Formerly MS39065-6
2.5 amp circuit breaker
Thermal 25 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments.
This item has been added to your cart!