About this product Boeing spec aircraft Circuit Breaker 2 1/2 amps. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 5925-01-142-7773 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 0.750 inches nominal |
Body Style | Single pole type |
Body Width | 0.562 inches nominal |
Bushing Length | 0.250 inches nominal |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.50 inches nominal |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400.0 single location |
Inclosure Protection Type For Which Designed | Corrosion resistant and explosion proof and dusttight and humidity resistant and sandtight and shockproof and vibrationproof |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push button |
Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.5 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500.0 ac single location and 2500.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
Mounting Surface To Terminal End Distance | 1.312 inches nominal |
Thread Size | 0.438 inches |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 30.0 dc single location |
Pole Quantity | 1 |
Reset Method | Manual |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab w/screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Un |
Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 minimum at 200 pct single location and 35.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25.0 deg celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Unpackaged Unit Weight | 25.0 grams |
Circuit Breaker
7.5 amp circuit breaker
Circuit Breaker
5 amp circuit breaker
Circuit Breaker
2.5 amp circuit breaker
Circuit Breaker
2 amp circuit breaker
Circuit Breaker
15 amp circuit breaker
Circuit Breaker
10 amp circuit breaker
35 amp thermal Circuit Breaker with manual reset. Ignition protected & sealed. For the harsh environments of truck, bus, off-road, construction & electric vehicles. Self locking mounting nut. Features: 30VDC or 120VAC, Open and closed construction, Auto
UPGH6616215301 circuit breaker
Three phase 15 amp Mil Spec thermal Circuit Breaker with high vibration resistance. 3 phase: one phase trips all. Trip free - Circuit Breaker cannot be maintained closed during an overload even with the Actuator button held closed.
2 amp thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.