About this product 6TC14-2-5 Circuit Breaker 2 1/2 amp. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 6TC14-2-5 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole two |
| Body Height | 1.530 inches maximum |
| Body Length | 1.1 inches maximum |
| Body Style | Multipole-single actuator type |
| Body Width | 1.781 inches maximum |
| Bushing Length | 0.250 inches nominal |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
| Center To Center Distance Between Terminals Parallel To Width | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent all locations |
| Frequency In Hertz | 400.0 all locations |
| Internal Trip Release Configuration | Series trip all locations |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac all locations |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000.0 ac all locations |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Thread Size | 0.469 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac all locations |
| Pole Quantity | 3 |
| Reset Method | Manual |
| Terminal Type And Quantity | 6 screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations |
| Trip Release Ambient Tempurature Rating | 160.0 degrees fahrenheit maximum all locations |
| Trip Release Characteristic | Time delay all locations |
| Trip Release Method | Thermal all locations |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 all locations |
Circuit Breaker
6TC14-7.5 Circuit Breaker
Circuit Breaker
6TC14-5 Circuit Breaker
Circuit Breaker
6TC14-4 Circuit Breaker
Circuit Breaker
6TC14-3 Circuit Breaker
Circuit Breaker
6TC14-20 Circuit Breaker
Circuit Breaker
6TC14-2 Circuit Breaker
Thermal 10 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments. With self locking insert for easy mounting.
100 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
6TC37-7.5 Circuit Breaker
2 1/2 amp Sensata Klixon thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
This item has been added to your cart!