About this product trip free, 2 screw terminal, aircraft use. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS25244-5 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Thread Size | 0.469 inches |
Thread Series Designator | Uns |
Thread Qty Per Inch (tpi) | 32 |
Terminal Type And Quantity | 2 screw |
Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
Specification Data | 96906-ms25244 government standard |
Reset Method | Manual |
Pole Quantity | 1 |
Mounting Surface To Terminal End Distance | 1.812 inches maximum |
Operating Voltage Type And Rating Per Pole In Volts | 115 ac single location and 28 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
Maximum Continuous Load Current Rating Per Pole | 5 amperes ac single location and 5 amperes dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Circuit Protection Type | Overcurrent single location |
Bushing Length | 0.250 inches nominal |
Case Material | Metal |
Center To Center Distance Between Terminals Parallel To Length | 0.703 inches nominal |
Body Style | Single pole type |
Body Width | 0.750 inches maximum |
Body Length | 1.094 inches maximum |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Trip Delay Time In Seconds Per Rated Continuous Current | 15 minimum at 200 pct single location and 55.000 maximum at 200 pct single location and 2.000 minimum at 400 pct single location and 7.000 maximum at 400 pct single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Circuit Breaker
MS25244712 circuit breaker
Circuit Breaker
5925-00-686-3299 nsn trip free MS2524435 circuit breaker
Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
Circuit Breaker
5925-00-805-2833 nsn trip free Milspec MS2524425 circuit breaker
Circuit Breaker
MS2524420 circuit breaker
Circuit Breaker
MS2524410 circuit breaker
AP16151153 circuit breaker
Thermal Circuit Breakers are designed to utilize less space behind the Panel while protecting wire & Cable in aircraft & ground support equipment. Toggle Switch style. 7 1/2 amps.
7 1/2 amp, aircraft circuit breaker, single phase, vibration resistance 2TC1475 circuit breaker
10 amp circuit breaker
This item has been added to your cart!