About this product 6TC14-2-5 Circuit Breaker 2 1/2 amp. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 6TC14-2-5 |
| Description | Circuit Breaker |
| Schedule B Class | 8536200040 |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole two |
| Body Height | 1.530 inches maximum |
| Body Length | 1.1 inches maximum |
| Body Style | Multipole-single actuator type |
| Body Width | 1.781 inches maximum |
| Bushing Length | 0.250 inches nominal |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
| Center To Center Distance Between Terminals Parallel To Width | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent all locations |
| Frequency In Hertz | 400.0 all locations |
| Internal Trip Release Configuration | Series trip all locations |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac all locations |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000.0 ac all locations |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Thread Size | 0.469 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac all locations |
| Pole Quantity | 3 |
| Reset Method | Manual |
| Terminal Type And Quantity | 6 screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations |
| Trip Release Ambient Tempurature Rating | 160.0 degrees fahrenheit maximum all locations |
| Trip Release Characteristic | Time delay all locations |
| Trip Release Method | Thermal all locations |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 all locations |
Circuit Breaker
6TC14-7.5 Circuit Breaker
Circuit Breaker
6TC14-5 Circuit Breaker
Circuit Breaker
6TC14-4 Circuit Breaker
Circuit Breaker
6TC14-3 Circuit Breaker
Circuit Breaker
6TC14-20 Circuit Breaker
Circuit Breaker
6TC14-2 Circuit Breaker
6752-100-60 Circuit Breaker
Three phase 15 amp Mil Spec thermal Circuit Breaker with high vibration resistance. 3 phase: one phase trips all. Trip free - Circuit Breaker cannot be maintained closed during an overload even with the Actuator button held closed.
Three Phase aircraft Circuit Breaker, lightweight, high performance, trip free design. rated 20 amps at 115VAC/ 400Hz. Airbus ASNE0459-200. Other amp ratings available.
Circuit Breaker. Military Spec thermal magnetic Circuit Breaker. Circuit protection unaffected by temperature fluctuations. High vibration resistance and high interrupting capacity. 70 amp.
This item has been added to your cart!