About this product 7 1/2 amp thermal aircraft and military Circuit Breaker with long button-single phase, miniature ambient compensated and trip free. High vibration resistance. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 5925-00-346-7991 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 0.781 inches maximum |
Body Style | Single pole type |
Body Width | 0.593 inches maximum |
Bushing Length | 0.250 inches nominal |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.500 inches nominal |
Circuit Protection Type | Overcurrent single location |
Frequency In Hertz | 400.0 single location |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 7.5 amperes ac single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500.0 ac single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.343 inches maximum |
Thread Size | 0.438 inches |
Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location |
Pole Quantity | 1 |
Reset Method | Manual |
Specification Data | 81343-ms3320 government standard |
Terminal Type And Quantity | 2 screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 minimum at 200 pct and 30.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius maximum single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Circuit Breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 7/16'' bushing. Uses minimum space. Light weight. Trip free. 2 1/2 AMP.
Circuit Breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 7/16'' bushing. Uses minimum space. Light weight. Trip free. 7 1/2 AMP.
Circuit Breaker
35 amp, Mil Spec / aerospace Circuit Breaker. Single phase, ambient compensated. Long, trouble free operation: 20,000 operating cycles High vibration resistance.
Circuit Breaker
Circuit Breaker
Circuit Breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 7/16'' bushing. Uses minimum space. Light weight. Trip free. 1/2 AMP.
Circuit Breaker
50 amp Mil Spec / aerospace Circuit Breaker. Single phase, ambient compensated. Long, trouble free operation: 20,000 operating cycles High vibration resistance. Also available in 2 1/2 to 35 amps.
35 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC single
Airbus replacement Circuit Breaker.
15 amp thermal Circuit Breaker with manual reset. Ignition protected & sealed. For the harsh environments of truck, bus, off-road, construction & electric vehicles. Self locking insert for easy mounting. Features: 30VDC or 120VAC, Open and closed constr
Sensata 2TC142 aircraft circuit breaker