About this product 7 1/2 amp thermal aircraft and military Circuit Breaker with long button-single phase, miniature ambient compensated and trip free. High vibration resistance. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 5925-00-346-7991 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 0.781 inches maximum |
| Body Style | Single pole type |
| Body Width | 0.593 inches maximum |
| Bushing Length | 0.250 inches nominal |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.500 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Frequency In Hertz | 400.0 single location |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 7.5 amperes ac single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500.0 ac single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.343 inches maximum |
| Thread Size | 0.438 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Specification Data | 81343-ms3320 government standard |
| Terminal Type And Quantity | 2 screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 minimum at 200 pct and 30.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25 degree celsius maximum single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Circuit Breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 7/16'' bushing. Uses minimum space. Light weight. Trip free. 2 1/2 AMP.
Circuit Breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 7/16'' bushing. Uses minimum space. Light weight. Trip free. 7 1/2 AMP.
Circuit Breaker
35 amp, Mil Spec / aerospace Circuit Breaker. Single phase, ambient compensated. Long, trouble free operation: 20,000 operating cycles High vibration resistance.
Circuit Breaker
Circuit Breaker
Circuit Breaker
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 7/16'' bushing. Uses minimum space. Light weight. Trip free. 1/2 AMP.
Circuit Breaker
50 amp Mil Spec / aerospace Circuit Breaker. Single phase, ambient compensated. Long, trouble free operation: 20,000 operating cycles High vibration resistance. Also available in 2 1/2 to 35 amps.
Sensata 5 amp circuit breaker
6TC2-15 Circuit Breaker
30 amp,3 phase,miniature,ambient compensated. Light weight,Trip free design AS58091 qualified . Protective Terminal barriers between each phase.
7277-2-25 Circuit Breaker
This item has been added to your cart!