About this product 2 amp circuit breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC12-2 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Trip Release Method | Thermal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Ambient Tempurature Rating | 25.0 deg celsius maximum single location |
Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct and 16.000 maximum at 200 pct single location |
Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct single location and |
Trip Delay Time In Seconds Per Rated Continuous Current | 16.000 maximum at 200 pct single location |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Thread Size | 0.438 inches |
Terminal Type And Quantity | 2 tab with screw |
Pole Quantity | 1 |
Reset Method | Manual |
Storage Type | General purpose warehouse |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac and 28.0 dc single location |
Operating Voltage Type And Rating Per Pole In Volts | 28.0 dc single location |
Mounting Surface To Terminal End Distance | 1.281 inches minimum and 1.343 inches maximum |
Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500.0 ac single location and |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 6000.0 dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500.0 ac and 6000.0 dc single location |
Maximum Continuous Load Current Rating Per Pole | 2.0 amperes ac single location and 2.0 amperes dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 2.0 amperes ac and 2.0 amperes dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Internal Trip Release Configuration | Series trip single location |
Inclosure Protection Type For Which Designed | Fungus resistant |
Inclosure Protection Type For Which Designed | Moisture resistant and fungus resistant |
Inclosure Protection Type For Which Designed | Moisture resistant and |
Frequency In Hertz | 400 single location |
Circuit Protection Type | Overcurrent single location |
Center To Center Distance Between Terminals Parallel To Length | 0.469 inches minimum and 0.531 inches maximum |
Bushing Length | 0.040 inches minimum and 0.055 inches maximum |
Case Material | Plastic |
Body Width | 0.531 inches minimum and 0.593 inches maximum |
Body Style | Single pole type |
Actuator Position Designation | At pole one |
Body Length | 0.719 inches minimum and 0.781 inches maximum |
Actuator Function | Trip-reset |
Unpackaged Unit Weight | 0.057 pounds |
Circuit Breaker
2.5 amp circuit breaker
Circuit Breaker
20 amp circuit breaker
Circuit Breaker
15 amp circuit breaker
Circuit Breaker
10 amp circuit breaker
Circuit Breaker
1 amp circuit breaker
Commercial aircraft Circuit Breaker. Thermal 3 phase, miniature, ambient compensated. Trip free and lightweight. Vibration pads improve mounting stability. 20 amps
Thermal 150 amp Circuit Breaker. Ignition protected and sealed.Manual reset. Over-current protection for harsh environments, vehicle, electric vehicle, battery chargers, marine, etc..
Commercial 10 amp Klixon thermal Circuit Breaker with auto reset. Ignition protected and sealed. For the harsh environments of truck, bus, off-road, construction, & electric vehicles.