About this product 7277-2-5 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7277-2-5 |
| Description | Circuit Breaker |
| Schedule B Class | 8536200040 |
| ECCN (Export Control Class) | EAR99 |
| Terminal Type And Quantity | 2 tab w/screw |
| Storage Type | General purpose warehouse |
| Specification Data | 96906-ms26574 government standard |
| Reset Method | Manual |
| Pole Quantity | 1 |
| Operating Voltage Type And Rating Per Pole In Volts | 200.0 ac single location and 28.0 dc single location |
| Mounting Surface To Terminal End Distance | 1.420 inches maximum |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800.0 ac single location and 800.0 dc single location |
| Maximum Continuous Load Current Rating Per Pole | 5.0 amperes ac single location and 5.0 amperes dc single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
| Frequency In Hertz | 400.0 single location |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Bushing Length | 0.359 inches nominal |
| Case Material | Metal |
| Body Style | Single pole type |
| Body Width | 0.580 inches maximum |
| Body Length | 0.780 inches maximum |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Thread Size | 0.438 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location |
27515-7 Circuit Breaker Insert
7274-11-1 Circuit Breaker
7274-2-10 Circuit Breaker, 5925-00-946-6880
200 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl