About this product 3TC27-30 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 3TC27-30 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Arc Quenching Method | Magnetic blowout |
Body Length | 1.100 inches maximum |
Body Style | Single pole type |
Body Width | 0.750 inches maximum |
Bushing Length | 0.250 inches nominal |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | Dustproof |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 30.0 amperes ac single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500.0 ac single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.218 inches nominal |
Thread Size | 0.468 inches |
Nonturn Device Length | 0.047 inches nominal |
Nonturn Device Location | At 12 oclock |
Nonturn Device Radius | 0.375 inches nominal |
Nonturn Device Width | 0.078 inches nominal |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location |
Pole Quantity | 1 |
Reset Method | Manual |
Special Handling Feature | Magnetic |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab w/screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 15.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25.0 deg celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
Circuit Breaker
3TC27-35 Circuit Breaker
Circuit Breaker
3TC27-25 Circuit Breaker
14500-5 Circuit Breaker Boot
30 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC single
Thermal commercial aircraft Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 15/32'' bushing. Uses minimum space. Light weight. Trip free. 7 1/2 AMP.
This item has been added to your cart!