About this product 3TC27-35 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 3TC27-35 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Terminal Type And Quantity | 2 tab with screw |
Storage Type | General purpose warehouse |
Special Handling Feature | Magnetic |
Reset Method | Manual |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location |
Nonturn Device Width | 0.078 inches nominal |
Nonturn Device Radius | 0.375 inches nominal |
Nonturn Device Location | At 12 oclock |
Nonturn Device Length | 0.047 inches nominal |
Mounting Surface To Terminal End Distance | 1.218 inches nominal |
Mounting Facility Type And Quantity | 1 threaded bushing |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500.0 ac single location |
Maximum Continuous Load Current Rating Per Pole | 35.0 amperes ac single location |
Manual Actuator Type And Quantity | 1 push-pull |
Main Contact Tripping Mechanism Type | Trip free |
Internal Trip Release Configuration | Series trip single location |
Inclosure Protection Type For Which Designed | Dustproof |
Frequency In Hertz | 400.0 single location |
Fragility Factor | Moderately rugged |
Circuit Protection Type | Overcurrent single location |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
Case Material | Plastic |
Body Width | 0.750 inches maximum |
Bushing Length | 0.250 inches nominal |
Body Length | 1.100 inches maximum |
Body Style | Single pole type |
Arc Quenching Method | Magnetic blowout |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Thread Size | 0.468 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 2 minimum at 200 pct single location and 15.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |