About this product 3TC14-30 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 3TC14-30 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Arc Quenching Method | Magnetic blowout |
Body Length | 1.100 inches maximum |
Body Style | Single pole type |
Body Width | 0.781 inches maximum |
Bushing Length | 0.250 inches nominal |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.740 inches nominal |
Circuit Protection Type | Overcurrent single location |
Fragility Factor | Moderately rugged |
Frequency In Hertz | 400.0 single location |
Inclosure Protection Type For Which Designed | Dustproof and fungus proof |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 30.0 amperes ac single location and 30.0 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000.0 ac single location and 6000.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.218 inches nominal |
Thread Size | 0.468 inches |
Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 30.0 dc single location |
Pole Quantity | 1 |
Reset Method | Manual |
Special Handling Feature | Magnetic |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 6 minimum at 200 pct single location and 35.000 maximum at 200 pct single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Magnetic-hydraulic single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
Circuit Breaker
3TC14-35 Circuit Breaker
Circuit Breaker
3TC14-25 Circuit Breaker
Circuit Breaker
3TC14-15 Circuit Breaker
6752-100-50 Circuit Breaker
7277275 circuit breaker
Circuit Breaker. 35 amp,3 phase,miniature,ambient compensated. Light weight,Trip free design AS58091 qualified . Protective Terminal barriers between each phase.
175 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl