About this product 2 unthreaded hole single mounting facility. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS24171-D1 |
Description | Relay |
Schedule B Class | 8536.41.0050 |
ECCN (Export Control Class) | 9A991.d |
Duty Type | Continuous |
Fragility Factor | Moderately rugged |
Main Contact Load Current Rating At Maximum Rated Voltage | 100 amperes dc inductive load |
Main Contact Load Current Rating At Maximum Rated Voltage | 200 amperes dc resistive load |
Main Contact Load Current Rating At Maximum Rated Voltage | 200.0 amperes dc motor load |
Main Contact Maximum Voltage Rating In Volts | 28.0 dc |
Mounting Facility Pattern | In-line single mounting facility |
Mounting Facility Type And Quantity | 2 unthreaded hole single mounting facility |
Nonpile-up Main Contact Arrangement | 1 pole, single throw, normally open, double make, momentary action |
Operating Voltage Rating And Type At Specificationified Temp | 28.0 volts dc 25 degree celsius single winding |
Overall Height | 3.710 inches nominal |
Overall Length | 4.500 inches maximum |
Overall Width | 2.000 inches maximum |
Purpose For Which Designed | General |
Specification Data | 96906-ms24171 government standard |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 4 threaded stud all functions |
Test Data Document | 81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
Time Delay | 0.01 seconds maximum fixed release time |
Time Delay | 0.025 seconds maximum fixed operate time |
Unthreaded Mounting Hole Diameter | 0.266 inches nominal single mounting facility |
Winding Dc Resistance Rating | 59.0 ohms minimum single winding |
Winding Quantity | 1 |
Cubic Measure | 33.39 cubic inches |
Coil Quantity | 1 |
Case Material | Metal |
Center To Center Distance Between Mounting Facilities Parallel T | 3 inches nominal single mounting facility |
Arc Quenching Method | Air |
Relay
0.256 inches single mounting facility and 0.276 inches single mounting facility
Switch Guard, MIL-G-7703, One Hole Mount for 3 Position Switches, Returns lever from up position to center position, Phenolic Red Lever, Keyway tab is Opposite Hinged End
Switch Guard, Black, metal lever, Flush/One-hole-mounted (OHM) Switch mounting. MS approved and QPL‘d per MIL-G-7703.; For use with 2 and 3 position Switches.; Insertion of pin through guard prevents accidental operation, Prevents transfer of single
Up position momentary and down position momentary and center position maintained
Rugged Mil/Aero Lever Lock Toggle Switch, Miniature Positive Action, 5A @ 28/ VDC, 3A @ 115VAC 400 Hertz, 2A @ 115 VAC 60 Hertz Resistive Load, D.P.D.T. ON-OFF-ON with Solder-Lug Terminals MS21027-A211 (MS21027A211).
This item has been added to your cart!