About this product 30 amp, single phase, miniature ambient compensated, trip free, 3TC2-30. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | MS14105-30 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Thread Size | 0.438 inches |
| Thread Series Designator | Un |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 2 tab with screw |
| Storage Type | General purpose warehouse |
| Specification Data | 96906-ms14105 government specification |
| Reset Method | Manual |
| Pole Quantity | 1 |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac and 28 dc single location |
| Mounting Surface To Terminal End Distance | 1.343 inches maximum |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000.0 ac and 6000.0 dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 30.0 amperes ac and 30.0 amperes dc single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Vibration resistant and shock resistant |
| Frequency In Hertz | 400 single location |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.704 inches nominal |
| Body Width | 0.781 inches maximum |
| Bushing Length | 0.25 inches nominal |
| Body Style | Single pole type |
| Actuator Position Designation | At pole one |
| Body Length | 1.094 inches maximum |
| Actuator Function | Trip-reset |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.00 minimum at 200 pct and 35.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
| Unpackaged Unit Weight | 0.067 pounds |
Circuit Breaker
Single phase, 35 amp, trip free MS1410535 circuit breaker Klixon 3TC2-35
Circuit Breaker
25 amp circuit breaker
Thermal 35 amp Circuit Breaker. Ignition protected and sealed. Manual reset. Over-current protection for harsh environments, vehicle, electric vehicle, battery chargers, marine, etc.
7270-1-3 Circuit Breaker, 5925-00-967-8685
25 amp,3 phase,miniature,ambient compensated. Light weight,Trip free design AS58091 qualified . Protective Terminal barriers between each phase.
7277-2-25 Circuit Breaker
This item has been added to your cart!