About this product 7277-2-5 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7277-2-5 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 0.780 inches maximum |
| Body Style | Single pole type |
| Body Width | 0.580 inches maximum |
| Bushing Length | 0.359 inches nominal |
| Case Material | Metal |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 5.0 amperes ac single location and 5.0 amperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800.0 ac single location and 800.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Mounting Surface To Terminal End Distance | 1.420 inches maximum |
| Thread Size | 0.438 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 200.0 ac single location and 28.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Specification Data | 96906-ms26574 government standard |
| Storage Type | General purpose warehouse |
| Terminal Type And Quantity | 2 tab w/screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location |
30 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC single
27515-9 Circuit Breaker Insert
Thermal 60 amp Circuit Breaker. Precision,sealed and ignition protected. Manual reset. Provides excellent over-current protection for harsh environments.
Thermal 10 amp Circuit Breaker for military vehicles and equipment where precise ultimate trip characteristics are required. Rugged construction. Auto reset. Formerly known as M13516/5-1. Call us for higher volume discounts!
This item has been added to your cart!