3TC2-30 Circuit Breaker

Part#: 3TC2-30 NSN: 5925-01-075-6783

About this product 30 amp, single phase, miniature ambient compensated, trip free, 3TC2-30. * Manufacturer certifications are shipped with your order FREE of charge

Product Details

Part Number or Model 3TC2-30
Description Circuit Breaker
Schedule B Class
ECCN (Export Control Class)
Actuator Function Trip-reset
Actuator Position Designation At pole one
Body Length 1.094 inches maximum
Body Style Single pole type
Body Width 0.781 inches maximum
Bushing Length 0.250 inches nominal
Case Material Plastic
Center To Center Distance Between Terminals Parallel To Length 0.704 inches nominal
Circuit Protection Type Overcurrent single location
End Application Mrap - rg-33
Fragility Factor Moderately rugged
Frequency In Hertz 400.0 single location
Inclosure Protection Type For Which Designed Vibration resistant and shock resistant
Internal Trip Release Configuration Series trip single location
Main Contact Tripping Mechanism Type Trip free
Manual Actuator Type And Quantity 1 push-pull
Maximum Continuous Load Current Rating Per Pole 30.0 amperes ac and 30.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole I 2000.0 ac and 6000.0 dc single location
Mounting Facility Type And Quantity 1 threaded bushing
Mounting Surface To Terminal End Distance 1.343 inches maximum
Thread Size 0.438 inches
Operating Voltage Type And Rating Per Pole In Volts 120.0 ac and 28.0 dc single location
Pole Quantity 1
Reset Method Manual
Specification Data 96906-ms14105 government specification
Storage Type General purpose warehouse
Terminal Type And Quantity 2 tab w/screw
Test Data Document 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as
Thread Qty Per Inch (tpi) 32
Thread Series Designator Un
Trip Delay Time In Seconds Per Rated Continuous Current 2.000 minimum at 200 pct and 35.000 maximum at 200 pct single location
Trip Release Ambient Tempurature Rating 25.0 deg celsius nominal single location
Trip Release Characteristic Time delay single location
Trip Release Method Thermal single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe 138.0 single location
Unpackaged Unit Weight 0.067 pounds

Add to Cart

Up to quantity 8 ships same day.
buy now $295.00
each
Request a quote Call for questions and assistance
  +1 (321) 802-5889
  • NSN (National stock number)
    5925-01-075-6783
  • ECCN (Export Control Class)

Alternate(s)

3TC2 Series Products

see all 3TC2 parts »
3TC2-35

Circuit Breaker
Single phase, 35 amp, trip free MS1410535 circuit breaker Klixon 3TC2-35

3TC2-25

Circuit Breaker
25 amp circuit breaker

3TC2-20

Circuit Breaker
20 amp circuit breaker

3TC2-15

Circuit Breaker
15 amp circuit breaker

More from

MS9166-14

90 degree angle bracket

MS91528-1E3B

MS915281E3B knob

4408

4408 fuse

MS25226-2-16

MS25226-2-16 Conductor Bus

Compare Now »
Clear | Hide
Notice

Item added to cart

This item has been added to your cart!