(321) 802-5889
(0)
About this product 7270-1-30 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7270-1-30 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 1.375 inches maximum |
| Body Style | Single pole type |
| Body Width | 0.750 inches maximum |
| Bushing Length | 0.250 inches nominal |
| Case Material | Metal |
| Center To Center Distance Between Terminals Parallel To Length | 0.906 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 toggle |
| Maximum Continuous Load Current Rating Per Pole | 30.0 amperes ac single location and 30.0 amperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500.0 ac single location and 6000.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.312 inches nominal |
| Thread Size | 0.469 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Terminal Type And Quantity | 2 screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 deg celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
30 amp thermal Circuit Breaker with manual reset. Ignition protected.& sealed. For the harsh environments of truck,bus,off-road,construction,& electric vehicles as well as marine. Features: 30VDC or 120VAC, Open and closed construction, Automatic and ma
7277-2-2 Circuit Breaker
7274-11-20 Circuit Breaker
6766-19-40 Circuit Breaker
This item has been added to your cart!