About this product 25 amp circuit breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 7270-1-25 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 1.375 inches maximum |
Body Style | Single pole type |
Body Width | 0.750 inches maximum |
Bushing Length | 0.250 inches nominal |
Case Material | Metal |
Center To Center Distance Between Terminals Parallel To Length | 0.906 inches nominal |
Circuit Protection Type | Overcurrent single location |
Frequency In Hertz | 400.0 single location |
Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 toggle |
Maximum Continuous Load Current Rating Per Pole | 25.0 amperes ac single location and 25.0 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500.0 ac single location and 6000.0 dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.312 inches nominal |
Thread Size | 0.469 inches |
Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
Pole Quantity | 1 |
Reset Method | Manual |
Specification Data | 96906-ms24509 government standard |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 screw |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Uns |
Trip Delay Time In Seconds Per Rated Continuous Current | 10 minimum at 200 pct single location and 60 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
3 AMP thermal commercial aircraft Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
Thermal 35 amp Circuit Breaker. Ignition protected and sealed. Manual reset. Over-current protection for harsh environments, vehicle, electric vehicle, battery chargers, marine, etc.
7277-2-15 Circuit Breaker
100 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
This item has been added to your cart!