About this product 2 1/2 amp, 2TC2-2-1/2 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC2-2-1/2 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Terminal Type And Quantity | 2 tab with screw |
Storage Type | General purpose warehouse |
Specification Data | 96906-ms3320-2-1/2 government standard |
Reset Method | Manual |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 115 ac single location and 28 dc single location |
Mounting Surface To Terminal End Distance | 1.343 inches maximum |
Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000 ac single location and 2500 dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.5 amperes dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Internal Trip Release Configuration | Series trip single location |
Inclosure Protection Type For Which Designed | Shock resistant and vibration resistant |
Frequency In Hertz | 400.0 single location |
Fragility Factor | Moderately rugged |
Circuit Protection Type | Overcurrent single location |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.5 inches nominal |
Body Width | 0.593 inches maximum |
Bushing Length | 0.250 inches nominal |
Body Style | Single pole type |
Body Length | 0.781 inches maximum |
Actuator Position Designation | At pole one |
Actuator Function | Trip-reset |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Un |
Thread Size | 0.438 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
Unpackaged Unit Weight | 0.055 pounds |
Circuit Breaker
2TC27-7-1/2 Circuit Breaker
Circuit Breaker
2TC27-5 Circuit Breaker
Circuit Breaker
2TC27-4 Circuit Breaker
Circuit Breaker
2TC27-2 Circuit Breaker
Circuit Breaker
2TC2712 circuit breaker
Circuit Breaker
2TC27-10 Circuit Breaker
Airbus replacement Circuit Breaker.
Aircraft Motor Protector. Non-Hermetic, Three phase Motor Protector 120 amps at 28Vdc, 120 amps at 120Vac
5 amp circuit breaker
10 amp thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
This item has been added to your cart!