About this product 2 1/2 amp, 2TC2-2-1/2 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 2TC2-2-1/2 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Terminal Type And Quantity | 2 tab with screw |
| Storage Type | General purpose warehouse |
| Specification Data | 96906-ms3320-2-1/2 government standard |
| Reset Method | Manual |
| Pole Quantity | 1 |
| Operating Voltage Type And Rating Per Pole In Volts | 115 ac single location and 28 dc single location |
| Mounting Surface To Terminal End Distance | 1.343 inches maximum |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000 ac single location and 2500 dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.5 amperes dc single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Shock resistant and vibration resistant |
| Frequency In Hertz | 400.0 single location |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.5 inches nominal |
| Body Width | 0.593 inches maximum |
| Bushing Length | 0.250 inches nominal |
| Body Style | Single pole type |
| Body Length | 0.781 inches maximum |
| Actuator Position Designation | At pole one |
| Actuator Function | Trip-reset |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Thread Size | 0.438 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138.0 single location |
| Unpackaged Unit Weight | 0.055 pounds |
Circuit Breaker
2TC27-7-1/2 Circuit Breaker
Circuit Breaker
2TC27-5 Circuit Breaker
Circuit Breaker
2TC27-4 Circuit Breaker
Circuit Breaker
2TC27-2 Circuit Breaker
Circuit Breaker
2TC2712 circuit breaker
Circuit Breaker
2TC27-10 Circuit Breaker
6752-100-70 Circuit Breaker
Thermal 20 amp Circuit Breaker for military vehicles and equipment where precise ultimate trip characteristics are required. Rugged construction. Auto reset. Formerly known as M13516/5-3
7277575 circuit breaker
6TC14-4 Circuit Breaker
This item has been added to your cart!