About this product 50 amp breaker for aircraft. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS25361-50 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138 single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Unc |
Thread Size | 0.138 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 15 minimum at 200 pct single location and 65.000 maximum at 200 pct single location |
Terminal Type And Quantity | 2 screw |
Storage Type | General purpose warehouse |
Reset Method | Manual |
Specification Data | 96906-ms25361 government standard |
Mounting Facility Type And Quantity | 2 threaded hole |
Mounting Surface To Terminal End Distance | 2.25 inches |
Operating Voltage Type And Rating Per Pole In Volts | 115 ac single location and 28 dc single location |
Pole Quantity | 1 |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 50 amperes ac single location and 50 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
Inclosure Protection Type For Which Designed | Moisture resistant and explosion resistant |
Distance Between Centerlines Of Mounting Facilities Parallel To | 1.812 inches nominal |
Frequency In Hertz | 400 single location |
Circuit Protection Type | Overcurrent single location |
Center To Center Distance Between Terminals Parallel To Length | 1.438 inches nominal |
Case Material | Metal |
Bushing Length | 0.25 inches nominal |
Body Width | 0.75 inches maximum |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 2.189 inches maximum |
Body Style | Single pole type |
Circuit Breaker
MS2536160 circuit breaker
Circuit Breaker
MS25361100 circuit breaker
Thermal 10 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments. With self locking insert for easy mounting.
Thermal Circuit Breaker. Sealed & ignition protected, hi amp, rugged. 175 amps. Automatic reset. Harness protection for heavy trucks, construction equipment, buses, off road vehicles. Formerly known as M13516/8-6.
10 amp thermal aircraft and military Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
Precision rugged 2 amp manual reset thermal Circuit Breaker for harsh environments.For applications such as military vehicles,etc.
This item has been added to your cart!