About this product 50 amp breaker for aircraft. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | MS25361-50 |
| Description | Circuit Breaker |
| Schedule B Class | 8536200040 |
| ECCN (Export Control Class) | EAR99 |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138 single location |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Unc |
| Thread Size | 0.138 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 15 minimum at 200 pct single location and 65.000 maximum at 200 pct single location |
| Terminal Type And Quantity | 2 screw |
| Storage Type | General purpose warehouse |
| Reset Method | Manual |
| Specification Data | 96906-ms25361 government standard |
| Mounting Facility Type And Quantity | 2 threaded hole |
| Mounting Surface To Terminal End Distance | 2.25 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 115 ac single location and 28 dc single location |
| Pole Quantity | 1 |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 50 amperes ac single location and 50 amperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
| Inclosure Protection Type For Which Designed | Moisture resistant and explosion resistant |
| Distance Between Centerlines Of Mounting Facilities Parallel To | 1.812 inches nominal |
| Frequency In Hertz | 400 single location |
| Circuit Protection Type | Overcurrent single location |
| Center To Center Distance Between Terminals Parallel To Length | 1.438 inches nominal |
| Case Material | Metal |
| Bushing Length | 0.25 inches nominal |
| Body Width | 0.75 inches maximum |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 2.189 inches maximum |
| Body Style | Single pole type |
Circuit Breaker
MS25361-60 Circuit Breaker, 5925-00-881-2463
Circuit Breaker
MS25361-100 Circuit Breaker
15 amp thermal aircraft and military Circuit Breaker single phase, miniature ambient compensated and trip free. High vibration resistance.
Thermal 90 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments.