About this product 50 amp breaker for aircraft. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | MS25361-50 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 138 single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Unc |
Thread Size | 0.138 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 15 minimum at 200 pct single location and 65.000 maximum at 200 pct single location |
Terminal Type And Quantity | 2 screw |
Storage Type | General purpose warehouse |
Reset Method | Manual |
Specification Data | 96906-ms25361 government standard |
Mounting Facility Type And Quantity | 2 threaded hole |
Mounting Surface To Terminal End Distance | 2.25 inches |
Operating Voltage Type And Rating Per Pole In Volts | 115 ac single location and 28 dc single location |
Pole Quantity | 1 |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 50 amperes ac single location and 50 amperes dc single location |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 3500 ac single location and 6000 dc single location |
Inclosure Protection Type For Which Designed | Moisture resistant and explosion resistant |
Distance Between Centerlines Of Mounting Facilities Parallel To | 1.812 inches nominal |
Frequency In Hertz | 400 single location |
Circuit Protection Type | Overcurrent single location |
Center To Center Distance Between Terminals Parallel To Length | 1.438 inches nominal |
Case Material | Metal |
Bushing Length | 0.25 inches nominal |
Body Width | 0.75 inches maximum |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 2.189 inches maximum |
Body Style | Single pole type |
Circuit Breaker
MS2536160 circuit breaker
Circuit Breaker
MS25361100 circuit breaker
Precision rugged 2 amp manual reset thermal Circuit Breaker for harsh environments.For applications such as military vehicles,etc.
IEG617215001V circuit breaker
Thermal 70 amp Circuit Breaker. Precision, sealed and ignition protected. Manual reset. Self locking mounting nut for easy installation. Provides excellent over-current protection for harsh environments. Same as Sensata Klixon PDLM-70 but with a self lock
175 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
This item has been added to your cart!