About this product 7274-4-7-1/2 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-4-7-1/2 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 2 tab w/screw |
| Switch Voltage Rating And Type In Volts | 120.0 ac and 30.0 dc |
| Switch Terminal Type | Tab, solder lug |
| Switch Location And Position Designation | Internal at pole one |
| Switch Current Rating And Type In Amps | 3.0 ac and 5.0 dc |
| Switch Contact Arrangement | Single pole, double throw |
| Storage Type | General purpose warehouse |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Specification Data | 81349-mil-c-5809 government specification |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 28 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Mounting Surface To Terminal End Distance | 1.525 inches maximum |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000 ac single location and 2500 dc single location |
| Maximum Continuous Load Current Rating Per Pole | 7.5 amperes ac single location and 7.5 amperes dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Corrosion resistant and dustproof and explosion resistant and fungus resistant and moisture resistant and sand resistant and vibration resistant |
| Frequency In Hertz | 400.0 single location |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Bushing Length | 0.250 inches nominal |
| Case Material | Plastic |
| Body Style | Single pole type |
| Body Width | 0.539 inches nominal |
| Body Length | 0.780 inches maximum |
| Actuator Position Designation | At pole one |
| Auxiliary Switch Function And Quantity | 1 alarm |
| Actuator Function | Trip-reset |
| Thread Series Designator | Un |
| Thread Size | 0.438 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
| Unpackaged Unit Weight | 0.066 pounds |
Thermal Circuit Breakers are designed to utilize less space behind the Panel while protecting wire & Cable in aircraft & ground support equipment. Toggle Switch style. 7 1/2 amps.
MS25361-100 Circuit Breaker
100 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
Thermal Circuit Breaker. Sealed & ignition protected, hi amp, rugged. 175 amps. Automatic reset. Harness protection for heavy trucks, construction equipment, buses, off road vehicles. Formerly known as M13516/8-6.