About this product 7274-2-25 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-2-25 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | |
| Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Thread Size | 0.438 inches |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Terminal Type And Quantity | 2 tab with screw |
| Storage Type | General purpose warehouse |
| Reset Method | Manual |
| Specification Data | 96906-ms26574 government standard |
| Pole Quantity | 1 |
| Operating Voltage Type And Rating Per Pole In Volts | 200 ac single location and 28 dc single location |
| Mounting Surface To Terminal End Distance | 1.42 inches maximum |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800 ac single location and 800 dc single location |
| Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.5 amperes dc single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
| Frequency In Hertz | 400 single location |
| Circuit Protection Type | Overcurrent single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Case Material | Metal |
| Bushing Length | 0.359 inches nominal |
| Body Width | 0.58 inches maximum |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 0.780 inches maximum |
| Body Style | Single pole type |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145 single location |
Circuit Breaker
7274-69-5 Circuit Breaker
Circuit Breaker
7274-69-4 Circuit Breaker
Circuit Breaker
7274-69-3/4 Circuit Breaker
Circuit Breaker
7274-69-3 Circuit Breaker
Circuit Breaker
7274-69-20 Circuit Breaker
Circuit Breaker
7274-69-2 Circuit Breaker
Circuit Breaker. Sealed & ignition protected, hi amp, rugged. 175 amps. Manual reset. Harness protection for heavy trucks, construction equipment, buses, off road vehicles. Formerly known as M13516/3-6.
Military Spec thermal magnetic Circuit Breaker. Circuit protection unaffected by temperature fluctuations. High vibration resistance and high interrupting capacity. 100 amp.
7274-4-5 Circuit Breaker
7271 thermal Circuit Breakers are designed to utilize less space behind the Panel while protecting wire & Cable in aircraft & ground support equipment. Push button style. 25 amps. Similar to 7271-8-25 but this version has a plate mount vs. the neck mount.
This item has been added to your cart!