About this product 2 1/2 amp, 7/16 inch bushing, trip free. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 7274-2-2.5 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Thread Size | 0.438 inches |
Thread Series Designator | Un |
Thread Qty Per Inch (tpi) | 32 |
Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
Specification Data | 96906-ms26574 government standard |
Storage Type | General purpose warehouse |
Terminal Type And Quantity | 2 tab with screw |
Pole Quantity | 1 |
Reset Method | Manual |
Operating Voltage Type And Rating Per Pole In Volts | 200 ac single location and 28 dc single location |
Manual Actuator Type And Quantity | 1 push-pull |
Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.5 amperes dc single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Mounting Surface To Terminal End Distance | 1.420 inches maximum |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800 ac single location and 800 dc single location |
Internal Trip Release Configuration | Series trip single location |
Main Contact Tripping Mechanism Type | Trip free |
Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
Circuit Protection Type | Overcurrent single location |
Frequency In Hertz | 400 single location |
Trip Delay Time In Seconds Per Rated Continuous Current | 2 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
Bushing Length | 0.359 inches nominal |
Case Material | Metal |
Body Style | Single pole type |
Body Width | 0.580 inches maximum |
Body Length | 0.780 inches maximum |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145 single location |
15 amp, 3 phase, miniature, ambient compensated. Light weight, Trip free design AS58091 qualified . Protective Terminal barriers between each phase.
MS33204 circuit breaker
30 amp thermal Circuit Breaker with manual reset. Ignition protected.& sealed. For the harsh environments of truck,bus,off-road,construction,& electric vehicles as well as marine. Features: 30VDC or 120VAC, Open and closed construction, Automatic and ma
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 7/16'' bushing. Uses minimum space. Light weight. Trip free. 1/2 AMP.