About this product 7274-11-2 Circuit Breaker, 5925-01-125-4870. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-11-2 |
| Description | Circuit Breaker |
| Schedule B Class | 8536.20.0020 |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Arc Quenching Method | Air |
| Body Length | 0.750 inches nominal |
| Body Style | Single pole type |
| Body Width | 0.562 inches nominal |
| Bushing Length | 0.250 inches nominal |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.703 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400 single location |
| Inclosure Protection Type For Which Designed | Corrosion resistant and sand resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 2 amperes ac single location and 2 amperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800 ac single location and 2000 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.707 inches nominal |
| Thread Size | 0.469 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location and 28 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Special Features | Ampere marked on actuator |
| Storage Type | General purpose warehouse |
| Terminal Type And Quantity | 2 tab with screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degrees celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location |