About this product 7274-11-10 Circuit Breaker, 5925-01-125-5719. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-11-10 |
| Description | Circuit Breaker |
| Schedule B Class | 8536.20.0020 |
| ECCN (Export Control Class) | EAR99 |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 2 tab with screw |
| Storage Type | General purpose warehouse |
| Special Features | Ampere marked on actuator |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 28.0 dc single location |
| Mounting Surface To Terminal End Distance | 1.707 inches nominal |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800.0 ac single location and 2000.0 dc single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 10.0 amperes ac single location and 10.0 amperes dc single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip single location |
| Inclosure Protection Type For Which Designed | Corrosion resistant and sand resistant |
| Frequency In Hertz | 400.0 single location |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent single location |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.703 inches nominal |
| Body Width | 0.562 inches nominal |
| Bushing Length | 0.250 inches nominal |
| Body Length | 0.750 inches nominal |
| Actuator Position Designation | At pole one |
| Arc Quenching Method | Air |
| Actuator Function | Trip-reset |
| Thread Series Designator | Uns |
| Thread Size | 0.469 inches |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location |
| Unpackaged Unit Weight | 1.500 ounces |
Military Spec thermal magnetic Circuit Breaker. Circuit protection unaffected by temperature fluctuations. High vibration resistance and high interrupting capacity. 50 amp.
100 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
Thermal 80 amp Circuit Breaker. Ignition protected and sealed. Manual reset. Over-current protection for harsh environments, vehicle, electric vehicle, battery chargers, marine, etc..
Thermal military/aerospace Circuit Breaker. Non compensated, high performance. 15/32'' bushing. Uses minimum space. Light weight. Trip free. 1/2 AMP.
This item has been added to your cart!