About this product 7270-1-20 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7270-1-20 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 1.375 inches maximum |
| Body Style | Single pole type |
| Body Width | 0.750 inches maximum |
| Bushing Length | 0.250 inches nominal |
| Case Material | Metal |
| Center To Center Distance Between Terminals Parallel To Length | 0.906 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Shock resistant and vibration resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 toggle |
| Maximum Continuous Load Current Rating Per Pole | 20.0 amperes ac single location and 20.0 amperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 5000.0 ac single location and 5000.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Mounting Surface To Terminal End Distance | 1.343 inches maximum |
| Thread Size | 0.469 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Specification Data | 96906-ms24509 government standard |
| Storage Type | General purpose warehouse |
| Terminal Type And Quantity | 2 tab w/screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 minimum at 200 pct single location and 70.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 all locations |
| Unpackaged Unit Weight | 0.087 pounds |
Boeing spec aircraft Circuit Breaker 2 1/2 amps.
25 AMP thermal commercial aircraft Circuit Breaker-single phase, miniature ambient compensated and trip free. High vibration resistance.
Thermal 70 amp Circuit Breaker. Precision, sealed and ignition protected. Manual reset. Self locking mounting nut for easy installation. Provides excellent over-current protection for harsh environments. Same as Sensata Klixon PDLM-70 but with a self lock