About this product 6TC2-7-1/2 Circuit Breaker 7 1/2 amp. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 6TC2-7-1/2 |
| Description | Circuit Breaker |
| Schedule B Class | 8536200040 |
| ECCN (Export Control Class) | EAR99 |
| Trip Delay Time In Seconds Per Rated Continuous Current | 4 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations and 0.400 minimum at 500 pct all locations and 2.000 maximum at 500 pct all locations and 0.100 minimum at 1000 pct all locations and 0.530 maximum at 1000 pct all locations |
| Thread Size | 0.438 inches |
| Thread Series Designator | Uns |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 6 screw |
| Reset Method | Manual |
| Pole Quantity | 3 |
| Mounting Facility Type And Quantity | Threaded bushing |
| Operating Voltage Type And Rating Per Pole In Volts | 120 ac all locations |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac all locations |
| Maximum Continuous Load Current Rating Per Pole | 7.5 amperes ac all locations |
| Manual Actuator Type And Quantity | 1 push-pull |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip all locations |
| Frequency In Hertz | 400.0 all locations |
| External Actuator Linkage Arrangement | One, two, and three linked |
| Circuit Protection Type | Overcurrent all locations |
| Center To Center Distance Between Terminals Parallel To Width | 0.593 inches minimum and 0.655 inches maximum |
| Center To Center Distance Between Terminals Parallel To Length | 0.469 inches minimum and 0.531 inches maximum |
| Body Style | Multipole-single actuator type |
| Body Width | 0.730 inches minimum and 0.770 inches maximum |
| Bushing Length | 0.219 inches minimum and 0.281 inches maximum |
| Case Material | Plastic |
| Body Length | 1.840 inches maximum |
| Body Height | 1.319 inches minimum and 1.381 inches maximum |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole two |
| Trip Release Ambient Tempurature Rating | 25 degree celsius maximum all locations |
| Trip Release Characteristic | Time delay all locations |
| Trip Release Method | Thermal all locations |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145 all locations |
Circuit Breaker
6TC26-7-1/2 Circuit Breaker
Circuit Breaker
6TC26-5 Circuit Breaker
Circuit Breaker
6TC26-2-1/2 Circuit Breaker
Circuit Breaker
6TC2-5 Circuit Breaker, 5925-01-086-5641
Circuit Breaker
6TC2-4 Circuit Breaker, 5925-01-173-7285
Circuit Breaker
6TC2-3 Circuit Breaker
Thermal 20 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments.
7271-8-3 Circuit Breaker
5925-01-227-4047 nsn milspec MS2524430 circuit breaker
Thermal 40 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments
This item has been added to your cart!