About this product 15 amp, single phase, aircraft use. MFG certifications included. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 2TC2-15 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | EAR99 |
Body Width | 0.562 inches maximum |
Bushing Length | 0.25 inches nominal |
Case Material | Plastic |
Center To Center Distance Between Terminals Parallel To Length | 0.704 inches |
Circuit Protection Type | Overcurrent single location |
Frequency In Hertz | 400 single location |
Inclosure Protection Type For Which Designed | General purpose |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 125 single location |
Trip Release Method | Thermal single location |
Trip Release Characteristic | Time delay single location |
Thread Size | 0.438 inches |
Trip Delay Time In Seconds Per Rated Continuous Current | 2.8 minimum at 200 pct single location and 40.000 maximum at 200 pct single location |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Thread Series Designator | Un |
Thread Qty Per Inch (tpi) | 32 |
Terminal Type And Quantity | 2 screw |
Reset Method | Manual |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 120 ac single location |
Mounting Facility Type And Quantity | 1 threaded bushing |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Mounting Surface To Terminal End Distance | 1.218 inches maximum |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500 ac single location |
Maximum Continuous Load Current Rating Per Pole | 15 amperes ac single location |
Actuator Function | Reset |
Actuator Position Designation | At pole one |
Body Length | 0.75 inches |
Internal Trip Release Configuration | Series trip single location |
Body Style | Single pole type |
Circuit Breaker
2TC27-7-1/2 Circuit Breaker
Circuit Breaker
2TC27-5 Circuit Breaker
Circuit Breaker
2TC27-4 Circuit Breaker
Circuit Breaker
2TC27-2 Circuit Breaker
Circuit Breaker
2TC2712 circuit breaker
Circuit Breaker
2TC27-10 Circuit Breaker
200 amp overload Sensor. Sensata Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 V
Thermal 70 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments.
15TC50-35 Circuit Breaker
8 amp thermal Circuit Breaker with auto reset. Ignition protected & sealed. For the harsh environments of truck, bus, off-road, construction & electric vehicles.
This item has been added to your cart!