(321) 802-5889
(0)
About this product 20 amp, 3 phase, Trip free and lightweight, MS14154-20 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | MS14154-20 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations |
| Thread Size | 0.438 inches |
| Thread Series Designator | Un |
| Thread Qty Per Inch (tpi) | 32 |
| Terminal Type And Quantity | 6 tab with screws |
| Specification Data | 96906-ms14154 government standard |
| Storage Type | General purpose warehouse |
| Pole Quantity | 3 |
| Reset Method | Manual |
| Operating Voltage Type And Rating Per Pole In Volts | 200 ac all locations |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2000 ac all locations |
| Maximum Continuous Load Current Rating Per Pole | 20 amperes ac all locations |
| Manual Actuator Type And Quantity | 1 push-pull |
| Main Contact Tripping Mechanism Type | Trip free |
| Internal Trip Release Configuration | Series trip all locations |
| Inclosure Protection Type For Which Designed | Shockproof and vibrationproof |
| Frequency In Hertz | 400 all locations |
| Fragility Factor | Moderately rugged |
| Circuit Protection Type | Overcurrent all locations |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.469 inches minimum and 0.531 inches maximum |
| Center To Center Distance Between Terminals Parallel To Width | 0.593 inches minimum and 0.655 inches maximum |
| Bushing Length | 0.219 inches minimum and 0.281 inches maximum |
| Body Style | Multipole-single actuator type |
| Body Width | 1.840 inches maximum |
| Body Height | 1.381 inches maximum |
| Body Length | 0.781 inches maximum |
| Arc Quenching Method | Magnetic blowout |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole two |
| Trip Release Ambient Tempurature Rating | 71.0 degree fahrenheit nominal all locations |
| Trip Release Characteristic | Time delay all locations |
| Trip Release Method | Thermal all locations |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 120.0 all locations |
Circuit Breaker
MS14154712 circuit breaker
Circuit Breaker
MS14154-5 Circuit Breaker
Circuit Breaker
MS14154-15 Circuit Breaker
Circuit Breaker
5925-01-085-1216 nsn milspec MS1415410 circuit breaker
MS3320-15 Circuit Breaker
84400057 circuit breaker
MS332025 circuit breaker
MS33202 circuit breaker