About this product 7277-2-1/2 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7277-2-1/2 |
| Description | Circuit Breaker |
| Schedule B Class | 8536200040 |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 0.750 inches nominal |
| Body Style | Single pole type |
| Body Width | 0.562 inches nominal |
| Bushing Length | 0.359 inches nominal |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Humidity resistant and vibration resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 500 milliamperes ac single location and 500.0 milliamperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 2500 ac single location and 1000.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Mounting Surface To Terminal End Distance | 1.420 inches maximum |
| Thread Size | 0.438 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 120.0 ac single location and 32.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Storage Type | General purpose warehouse |
| Terminal Type And Quantity | 2 tab w/screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Uns |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2 minimum at 200 pct single location and 35.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
175 amp overload Sensor. Klixon 7235 and 7236 overload sensing controls are designed for the remote sensing of overloads in aircraft electrical systems or other appliCable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC singl
Circuit Breaker, Type 3 phase, push-pull, trip free, 35 amps. FAA approved part number 10-60806-1035
27515-11 Circuit Breaker Insert
MS24510B712 circuit breaker