About this product 7274-4-3 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-4-3 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Auxiliary Switch Function And Quantity | 1 control |
| Body Length | 0.780 inches maximum |
| Body Style | Single pole type |
| Body Width | 0.580 inches maximum |
| Bushing Length | 0.359 inches nominal |
| Case Material | Metal |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 3.0 amperes ac single location and 3.0 amperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 100.0 ac single location and 100.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.420 inches maximum |
| Thread Size | 0.438 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Storage Type | General purpose warehouse |
| Switch Contact Arrangement | Single pole, single throw, normally closed |
| Switch Current Rating And Type In Amps | 3.0 ac and 3.0 dc |
| Switch Location And Position Designation | External at pole one |
| Switch Terminal Type | Tab, solder lug |
| Switch Voltage Rating And Type In Volts | 115.0 ac and 28.0 dc |
| Terminal Type And Quantity | 2 screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location |
7271 thermal Circuit Breakers are designed to utilize less space behind the Panel while protecting wire & Cable in aircraft & ground support equipment. Push button style. 15 amps. Similar to 7271-8-10 but this version has a plate mount vs. the neck mount.
3-phase, 50 amp, also known as NSA931304-5005, ambient compensated aircraft grade thermal Circuit Breaker. Klixon 6752-300 series thermal magnetic Circuit Breakers are designed and manufactured to meet more stringent military standards of today's jet airc
Thermal 40 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments