About this product 7274-4-1/2 Circuit Breaker 4.5 amp. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-4-1/2 |
| Description | Circuit Breaker |
| Schedule B Class | |
| ECCN (Export Control Class) | EAR99 |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Auxiliary Switch Function And Quantity | 1 control |
| Body Length | 0.780 inches maximum |
| Body Width | 0.580 inches maximum |
| Bushing Length | 0.359 inches nominal |
| Case Material | Metal |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Moisture resistant and explosion resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 500.0 milliamperes ac single location and 500.0 milliamperes dc single location |
| Maximum Continuous Load Current Rating Per Pole | 500.0 milliamperes ac and 500.0 milliamperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 100.0 ac single location and 100.0 dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 100.0 ac and 100.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.420 inches maximum |
| Thread Size | 0.438 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac and 28.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Specification Data | 96906-ms26574 government standard |
| Switch Contact Arrangement | Single pole, single throw, normally closed |
| Switch Current Rating And Type In Amps | 0.5 ac and 0.5 dc |
| Switch Location And Position Designation | External at pole one |
| Switch Terminal Type | Tab, solder lug |
| Switch Voltage Rating And Type In Volts | 115.0 ac and 28.0 dc |
| Terminal Type And Quantity | 2 screw |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 degree celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location |
AP61R382961 circuit breaker
15 amp aircraft circuit breaker
35 AMP mil/aero thermal Circuit Breaker. Klixon 9TC series Circuit Breakers provide ambient compensated circuit protection in a lightweight, sub-miniature package size. The three phase integrally linked design provides overcurrent protection in the event
Circuit Breaker. Precision, rugged 15 amp manual reset thermal Circuit Breaker for harsh environments. For applications such as military vehicles, etc. Neck bushing mount style.
This item has been added to your cart!