About this product 7274-2-25 Circuit Breaker. * Manufacturer certifications are shipped with your order FREE of charge
Part Number or Model | 7274-2-25 |
Description | Circuit Breaker |
Schedule B Class | |
ECCN (Export Control Class) | |
Trip Release Ambient Tempurature Rating | 25 degree celsius nominal single location |
Trip Delay Time In Seconds Per Rated Continuous Current | 2 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
Thread Size | 0.438 inches |
Thread Qty Per Inch (tpi) | 32 |
Thread Series Designator | Un |
Terminal Type And Quantity | 2 tab with screw |
Storage Type | General purpose warehouse |
Reset Method | Manual |
Specification Data | 96906-ms26574 government standard |
Pole Quantity | 1 |
Operating Voltage Type And Rating Per Pole In Volts | 200 ac single location and 28 dc single location |
Mounting Surface To Terminal End Distance | 1.42 inches maximum |
Mounting Facility Type And Quantity | 1 threaded bushing |
Maximum Interrupting Capacity Current Type And Rating Per Pole I | 800 ac single location and 800 dc single location |
Maximum Continuous Load Current Rating Per Pole | 2.5 amperes ac single location and 2.5 amperes dc single location |
Main Contact Tripping Mechanism Type | Trip free |
Manual Actuator Type And Quantity | 1 push-pull |
Internal Trip Release Configuration | Series trip single location |
Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
Frequency In Hertz | 400 single location |
Circuit Protection Type | Overcurrent single location |
Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
Case Material | Metal |
Bushing Length | 0.359 inches nominal |
Body Width | 0.58 inches maximum |
Actuator Function | Trip-reset |
Actuator Position Designation | At pole one |
Body Length | 0.780 inches maximum |
Body Style | Single pole type |
Trip Release Characteristic | Time delay single location |
Trip Release Method | Thermal single location |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145 single location |
Circuit Breaker
7274-69-5 Circuit Breaker
Circuit Breaker
7274-69-4 Circuit Breaker
Circuit Breaker
7274-69-3/4 Circuit Breaker
Circuit Breaker
7274-69-3 Circuit Breaker
Circuit Breaker
7274-69-20 Circuit Breaker
Circuit Breaker
7274-69-2 Circuit Breaker
Thermal 10 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Provides excellent over-current protection for harsh environments. With self locking insert for easy mounting.
15TC50-35 Circuit Breaker
Thermal 20 amp Circuit Breaker. Precision,sealed and ignition protected. Auto reset. Self locking mounting nut for easy installation. Excellent over-current protection for harsh environments.
Circuit Breaker. Precision, rugged 15 amp manual reset thermal Circuit Breaker for harsh environments. For applications such as military vehicles, etc. Neck bushing mount style.
This item has been added to your cart!