About this product 7274-2-10 Circuit Breaker, 5925-00-946-6880. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-2-10 |
| Description | Circuit Breaker |
| Schedule B Class | 8536200040 |
| ECCN (Export Control Class) | |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 0.750 inches nominal |
| Body Style | Single pole type |
| Body Width | 0.562 inches nominal |
| Bushing Length | 0.395 inches nominal |
| Case Material | Plastic |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Fragility Factor | Moderately rugged |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Moisture resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 10.0 amperes ac single location and 10.0 amperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 500.0 ac single location and 500.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Mounting Surface To Terminal End Distance | 1.420 inches nominal |
| Thread Size | 0.438 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 200.0 ac single location and 28.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Special Handling Feature | Magnetic |
| Specification Data | 96906-ms26574 government standard |
| Storage Type | General purpose warehouse |
| Terminal Type And Quantity | 2 tab w/screw |
| Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Magnetic single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 150.0 single location |
Circuit Breaker
Sensata 7274-69-5 Circuit Breaker
Circuit Breaker
7274-69-4 Circuit Breaker
Circuit Breaker
7274-69-3/4 Circuit Breaker
Circuit Breaker
7274-69-3 Circuit Breaker
Circuit Breaker
7274-69-20 Circuit Breaker
Circuit Breaker
7274-69-2 Circuit Breaker
7271 thermal Circuit Breakers are designed to utilize less space behind the Panel while protecting wire & Cable in aircraft & ground support equipment. Push button style. 15 amps. Similar to 7271-8-10 but this version has a plate mount vs. the neck mount.
7274-2-25 Circuit Breaker
Thermal 60 amp Circuit Breaker. Ignition protected and sealed.. Auto reset. Over-current protection for harsh environments,vehicle,electric vehicle,battery chargers,marine,etc..
3SB4 series aircraft simulator only Circuit Breaker for simulators. Single phase, low amp, quick trip. No (null) rating insert. Inserts sold separately see 27515 series.
This item has been added to your cart!