About this product 7274-2-1/2 is a Sensata KLIXON 7274 Series 0.5-amp thermal aircraft circuit breaker featuring a trip-free, indicating push-to-reset design and 7/16-inch mounting bushing. Designed for high-performance aerospace and military electrical applications, the lightweight single-pole breaker is suitable for 28/30 VDC and 120 VAC 400 Hz systems. 7274-2-1/2 cross-references to MS26574-1/2 and is associated with NSN 5925-00-946-6879. * Manufacturer certifications are shipped with your order FREE of charge
| Part Number or Model | 7274-2-1/2 |
| Description | Circuit Breaker |
| Schedule B Class | 8536200040 |
| ECCN (Export Control Class) | |
| Actuator Function | Trip-reset |
| Actuator Position Designation | At pole one |
| Body Length | 0.780 inches maximum |
| Body Style | Single pole type |
| Body Width | 0.580 inches maximum |
| Bushing Length | 0.359 inches nominal |
| Case Material | Metal |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Circuit Protection Type | Overcurrent single location |
| Frequency In Hertz | 400.0 single location |
| Inclosure Protection Type For Which Designed | Explosion resistant and moisture resistant |
| Internal Trip Release Configuration | Series trip single location |
| Main Contact Tripping Mechanism Type | Trip free |
| Manual Actuator Type And Quantity | 1 push-pull |
| Maximum Continuous Load Current Rating Per Pole | 500.0 milliamperes ac single location and 500.0 milliamperes dc single location |
| Maximum Interrupting Capacity Current Type And Rating Per Pole I | 100.0 ac single location and 100.0 dc single location |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Mounting Surface To Terminal End Distance | 1.420 inches maximum |
| Thread Size | 0.438 inches |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
| Pole Quantity | 1 |
| Reset Method | Manual |
| Terminal Type And Quantity | 2 screw |
| Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as |
| Thread Qty Per Inch (tpi) | 32 |
| Thread Series Designator | Un |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Trip Release Ambient Tempurature Rating | 25.0 deg celsius nominal single location |
| Trip Release Characteristic | Time delay single location |
| Trip Release Method | Thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe | 145.0 single location |
Circuit Breaker
Sensata 7274-69-5 Circuit Breaker
Circuit Breaker
7274-69-4 Circuit Breaker
Circuit Breaker
7274-69-3/4 Circuit Breaker
Circuit Breaker
7274-69-3 Circuit Breaker
Circuit Breaker
7274-69-20 Circuit Breaker
Circuit Breaker
7274-69-2 Circuit Breaker
MS2657412 circuit breaker
7274-4-10 Circuit Breaker
14500-1 Circuit Breaker Boot
Thermal Circuit Breaker. Sealed & ignition protected, hi amp, rugged. 200 amps. Manual reset. Harness protection for heavy trucks, construction equipment, buses, off road vehicles. Formerly known as M13516/3-7 & MS29064-2.
This item has been added to your cart!